Upgrading Extreme Management Center Engine Software

28 of 34

Reinstalling Engine Software

Use the procedure in this chapter to reinstall the engine software, in the event a
software reinstall becomes necessary. Be aware this procedure reformats the
hard drive and reinstalls all the engine software, the operating system, and all
related Linux packages.

Connect a monitor and a USB keyboard to the engine prior to performing these
steps.

1. Download the Engine Image 64-bit upgrade file to your system.

To download an engine image:

1. Access the Extreme Portal at:

https://extremeportal.force.com/

.

2. After entering your email address and password, you are on the Support page.

3. Click the Products tab and select ExtremeManagement.

4. Click ExtremeManagement in the right-panel.

5. Select a version.

6. Download the image and extract the file to a directory on your system.

2. Insert the USB flash drive that came with the engine into the USB port on your

system and note the drive letter it is assigned.

3. Open a command prompt window and cd to the directory where you extracted the

file.

4. Type

make_disk.bat <drive letter>:

.

Note: Because the reinstall procedure reformats the drive, be sure you
have specified the correct drive letter.

5. Press [Enter].

The files are copied to the USB flash drive. When the copy is complete
you see the message:

Successfully installed into <drive letter>: Press any key

to continue.

6. Remove the USB flash drive from your system.

7. Insert the USB flash drive into a USB port on the engine (see

Front Panel Features

).

8. Boot the engine from the USB drive using either of these two methods.

Method 1:

Summary of Contents for Extreme Management Center NMS-A-305

Page 1: ...Extreme Management Center NMS A 305 Installation Guide 12 2019 9036579 00 Subject to Change Without Notice...

Page 2: ...ered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned in this document are the property of their respective owners a...

Page 3: ...orum for Extreme customers to connect with one another get questions answered share ideas and feedback and get problems solved This community is monitored by Extreme Networks employees but is not inte...

Page 4: ...y Status Indicator Patterns 12 Removing and Installing the Front Bezel 12 Removing the Front Bezel 13 Installing the Front Bezel 13 Installing the Engine into a Rack 13 Torque Values 14 Configuration...

Page 5: ...ng Extreme Management Center Engine Software 26 Reinstalling Engine Software 28 Product Regulatory and Compliance Information 30 Federal Communications Commission FCC Notice 30 Industry Canada Class A...

Page 6: ...stallation and initial configuration of the Extreme Networks Extreme Management Center NMS A 305 hardware engine This document is intended for experienced network administrators who are responsible fo...

Page 7: ...support motherboards server sb g23122003_ safetyregulatory pdf http www extremenetworks com support documentation Kit Contents The NMS A 305 engine ships with the following components l Extreme Netwo...

Page 8: ...IC Four RJ 45 Serial 9 pin DTE 16550 compatible USB Three 4 pin USB 2 0 compliant Video 15 pin VGA Networking Two 1 GB Ethernet Front USB Two 4 pin USB 2 0 compliant Video 15 pin VGA Power AC power su...

Page 9: ...sine 2 g force peak 11 milliseconds Shock unpackaged Trapezoidal 25 g velocity change 136 inches second 40 lb to 80 lb Shock packaged Non palletized free fall in height 24 inches 40 lb to 80 lb ESD 1...

Page 10: ...status LED B NMI button recessed tool required for use G Power button w integrated LED C Mgmt port activity LED H Hard drive activity LED D Not used I Not used E System cold reset button J Not used H...

Page 11: ...No access or no fault Solid amber Hard drive fault has occurred Hard Drive Status LED Indicator Patterns Back Panel Features This section shows the back panel and describes the major features NMS A 3...

Page 12: ...C power to all power supplies 1 Hz blinking green AC present Only 12VSB on PS off or PS in cold redundant state Amber AC power cord unplugged or AC power lost With a 2nd PS in parallel still with AC i...

Page 13: ...le 2 Rotate the front bezel clockwise till the left end clicks into place 3 Lock the bezel if needed Installing the Engine into a Rack A rack mounting kit and installation guide are included with the...

Page 14: ...ing table describes the recommended torque values to use when installing the engine using standard threaded fastener machine screws and bolts Screw Size Torque in Pounds Bit Size English Metric 5 Nomi...

Page 15: ...tion prior to executing the configuration steps in the next section l Engine hostname IP address and netmask l Default gateway IP address l Name server IP address and domain name l NIS Network Informa...

Page 16: ...ot be provided the prompt will indicate that the item is either Required or Optional The enter key may be pressed without entering data for Optional items A value must be entered for Required items At...

Page 17: ...ser if you already have a user defined on the machine and enter the user name Leave the name set to root if you do not want to specify another user Accept your selection Enter n to create a new netsig...

Page 18: ...tings screen you can accept the current configuration or modify the settings Confirm Network Settings These are the settings you have entered Enter 0 or any key other than a valid selection to continu...

Page 19: ...Time Protocol NTP server Enter y to use NTP and enter your NTP server IP address es Enter n to configure the date and time manually and proceed to step 11 Configure Date And Time Settings The engine d...

Page 20: ...elow 144 131 10 120 144 131 10 121 0 Accept the current settings 1 Restart NTP server selection 2 Set date and time manually Enter selection 0 0 11 If you answered no to using an NTP server to set dat...

Page 21: ...se UTC The system clock can be set to use UTC Specifying no for using UTC sets the hardware clock using localtime Do you want to use UTC y n n 13 In the Set Time Zone screen select the appropriate tim...

Page 22: ...or any key other than a valid selection to continue If you need to make a change enter the appropriate number from the choices listed below 0 Accept settings and continue 1 Set the root user password...

Page 23: ...er For example http 10 20 30 40 8080 or https 10 20 30 40 8443 The Extreme Management Center Launch Page opens 2 Launch your Extreme Management Center applications by clicking on the names or icons of...

Page 24: ...e the Syslog Log Manager to point to the new location on the engine This allows the display of syslog information in the Syslog Event View tab 1 From the Console menu bar select Tools Alarm Event Even...

Page 25: ...ks NetSight appdata InventoryMgr 4 Click OK Changing Engine Settings Use these steps if you need to change your Extreme Management Center engine settings following your initial engine configuration Ch...

Page 26: ...ine Image 64 bit upgrade file to your system To download an engine image 1 Access the Extreme Portal at https extremeportal force com 2 After entering your email address and password you are on the Su...

Page 27: ...34 The upgrade automatically begins The Extreme Management Center Server is restarted automatically when the upgrade is complete Because your engine settings were migrated you are not required to perf...

Page 28: ...ct ExtremeManagement 4 Click ExtremeManagement in the right panel 5 Select a version 6 Download the image and extract the file to a directory on your system 2 Insert the USB flash drive that came with...

Page 29: ...the power button and then press F2 to go to the BIOS setup 2 Use the arrow keys to navigate to the Boot Options menu 3 Ensure that the USB flash drive is listed as Boot Option 1 at the top 4 Save chan...

Page 30: ...oduct uses generates and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference to radio communication...

Page 31: ...mat riel brouilleur Appareils Num riques NMB 003 dict e par le Ministre Canadian des Communications CE Notice This product has been determined to be in compliance with 2006 95 EC Low Voltage Directiv...

Page 32: ...rical and electronic equipment WEEE 1 The symbol above indicates that separate collection of electrical and electronic equipment is required 2 When this product has reached the end of its serviceable...

Page 33: ...European Waste Electrical and Electronic Equipment WEEE Notice 33 of 34 For information about the available collection system please contact Extreme Customer Support at 353 61 705500 Ireland...

Page 34: ...Product Standards EC Directive 2004 108 EC EN55022 2006 A1 2007 EN 55024 1998 A1 2001 A2 2003 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EC Directive 2006 95 EC EN 60950 1 2006 A1 2009 EN 608...

Reviews: