background image

Hazardous Substances

32 of 34

measures.

Hazardous Substances

This product complies with the requirements of Directive 2011/65/EU of the
European Parliament and of the Council of 8 June 2011 on the restriction of the
use of certain hazardous substances in electrical and electronic equipment.

European Waste Electrical and Electronic
Equipment (WEEE) Notice

In accordance with Directive 2012/19/EU of the European Parliament on waste
electrical and electronic equipment (WEEE):

1. The symbol above indicates that separate collection of electrical and electronic

equipment is required.

2. When this product has reached the end of its serviceable life, it cannot be disposed

of as unsorted municipal waste. It must be collected and treated separately.

3. It has been determined by the European Parliament that there are potential negative

effects on the environment and human health as a result of the presence of
hazardous substances in electrical and electronic equipment.

4. It is the users’ responsibility to utilize the available collection system to ensure WEEE

is properly treated.

Summary of Contents for Extreme Management Center NMS-A-25

Page 1: ...Extreme Management Center NMS A 25 Installation Guide 12 2019 9036578 00 Subject to Change Without Notice...

Page 2: ...ered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned in this document are the property of their respective owners a...

Page 3: ...orum for Extreme customers to connect with one another get questions answered share ideas and feedback and get problems solved This community is monitored by Extreme Networks employees but is not inte...

Page 4: ...11 Removing and Installing the Front Bezel 12 Removing the Front Bezel 12 Installing the Front Bezel 12 Installing the Engine into a Rack 13 Torque Values 14 Configuration 15 Pre Configuration Tasks...

Page 5: ...gement Center Engine Software 26 Reinstalling Engine Software 28 Product Regulatory and Compliance Information 30 Federal Communications Commission FCC Notice 30 Industry Canada Class A 31 CE Notice 3...

Page 6: ...es the installation and initial configuration of the Extreme Management Center NMS A 25 hardware engine This document is intended for experienced network administrators who are responsible for impleme...

Page 7: ...sb g23122003_ safetyregulatory pdf http www extremenetworks com support documentation Kit Contents The NMS A 25 engine ships with the following components l Extreme Networks URL card l Front bezel la...

Page 8: ...VGA Power AC power supply per power supply Redundant power supply Wattage 750 watts Input voltage l 90 132V at 47 63 Hz 8 2A l 180 264 V at 47 63 Hz 4 4 A Output voltage l 62 0A at 12V l 2 1A at 12VSB...

Page 9: ...0 lb Shock packaged Non palletized free fall in height 24 inches 40 lb to 80 lb ESD 12 KV except I O port 8 KV per Intel Environmental test specification Estimated thermal dissipation 1550 BTU Hr Fron...

Page 10: ...he front of the system one is a green LED for disk activity and the other is amber and indicates hard drive status The following tables describe the LED states Activity LED Patterns Hard Drive Conditi...

Page 11: ...tatus Indication Network speed right Off 10 Mbps Amber 100 Mbps Green 1000 Mbps Link activity left Off No link Solid Green Active link Blinking Green Data traffic activity RJ45 Port LEDs Management Po...

Page 12: ...us LED Indicator Patterns Removing and Installing the Front Bezel The NMS A 25 engine comes with an optional front panel bezel that can be attached to the front of the chassis by snapping the bezel on...

Page 13: ...inet Refer to the installation guide for complete installation instructions If you are table mounting the engine ensure at least 6 cm 2 4 in of clearance on all sides of the engine for proper ventilat...

Page 14: ...e using standard threaded fastener machine screws and bolts Screw Size Torque in Pounds Bit Size English Metric 5 Nominal 5 N A N A 1 42 1 5 1 57 0 2 56 1 5 2 85 3 0 3 15 0 4 40 2 5 4 75 5 0 5 25 0 1...

Page 15: ...tion prior to executing the configuration steps in the next section l Engine hostname IP address and netmask l Default gateway IP address l Name server IP address and domain name l NIS Network Informa...

Page 16: ...ot be provided the prompt will indicate that the item is either Required or Optional The enter key may be pressed without entering data for Optional items A value must be entered for Required items At...

Page 17: ...ser if you already have a user defined on the machine and enter the user name Leave the name set to root if you do not want to specify another user Accept your selection Enter n to create a new netsig...

Page 18: ...tings screen you can accept the current configuration or modify the settings Confirm Network Settings These are the settings you have entered Enter 0 or any key other than a valid selection to continu...

Page 19: ...Time Protocol NTP server Enter y to use NTP and enter your NTP server IP address es Enter n to configure the date and time manually and proceed to step 11 Configure Date And Time Settings The engine d...

Page 20: ...es listed below 144 131 10 120 144 131 10 121 0 Accept the current settings 1 Restart NTP server selection 2 Set date and time manually Enter selection 0 0 If you answered no to using an NTP server to...

Page 21: ...use UTC Use UTC The system clock can be set to use UTC Specifying no for using UTC sets the hardware clock using localtime Do you want to use UTC y n n 2 In the Set Time Zone screen select the appropr...

Page 22: ...r any key other than a valid selection to continue If you need to make a change enter the appropriate number from the choices listed below 0 Accept settings and continue 1 Set the root user password 2...

Page 23: ...number For example http 10 20 30 40 8080 The Extreme Management Center Launch Page opens 2 Launch your Extreme Management Center applications by clicking on the names or icons of any of the listed app...

Page 24: ...e the Syslog Log Manager to point to the new location on the engine This allows the display of syslog information in the Syslog Event View tab 1 From the Console menu bar select Tools Alarm Event Even...

Page 25: ...rks NetSight appdata InventoryMgr 4 Click OK Changing Engine Settings Use these steps if you need to change your Extreme Management Center engine settings following your initial engine configuration C...

Page 26: ...ine Image 64 bit upgrade file to your system To download an engine image 1 Access the Extreme Portal at https extremeportal force com 2 After entering your email address and password you are on the Su...

Page 27: ...e automatically begins The Extreme Management Center Server is restarted automatically when the upgrade is complete Because your Extreme Management Center engine settings were migrated you are not req...

Page 28: ...ct ExtremeManagement 4 Click ExtremeManagement in the right panel 5 Select a version 6 Download the image and extract the file to a directory on your system 2 Insert the USB flash drive that came with...

Page 29: ...the power button and then press F2 to go to the BIOS setup 2 Use the arrow keys to navigate to the Boot Options menu 3 Ensure that the USB flash drive is listed as Boot Option 1 at the top 4 Save chan...

Page 30: ...oduct uses generates and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference to radio communication...

Page 31: ...mat riel brouilleur Appareils Num riques NMB 003 dict e par le Ministre Canadian des Communications CE Notice This product has been determined to be in compliance with 2006 95 EC Low Voltage Directiv...

Page 32: ...rical and electronic equipment WEEE 1 The symbol above indicates that separate collection of electrical and electronic equipment is required 2 When this product has reached the end of its serviceable...

Page 33: ...European Waste Electrical and Electronic Equipment WEEE Notice 33 of 34 For information about the available collection system please contact Extreme Customer Support at 353 61 705500 Ireland...

Page 34: ...Product Standards EC Directive 2004 108 EC EN55022 2006 A1 2007 EN 55024 1998 A1 2001 A2 2003 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EC Directive 2006 95 EC EN 60950 1 2006 A1 2009 EN 608...

Reviews: