ENGLISH
OperatIOn and lOGIc
IGnItIOn
once the previously listed points have been checked, press the
OK
key for three seconds to ignite the stove.
15 minutes are available for the ignition phase. After ignition and after reaching the control temperature, the
stove interrupts the ignition phase and switches to prepArATIon.
preparatIOn
during the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WorK.
wOrk
during the work phase, the stove reaches the set power set; see following item.
reGUlatIOn OF Set pOwer
The set power has 5 operating levels, When the
OK
key is pressed, the set power is displayed; it can be changed using the
OK
or
OK
keys.
power 1 = minimum level - power 5 = maximum level.
The change must be confirmed by pressing the key
OK
.
adJUStment OF Set h2O temperatUre
Set the boiler temperature from 65 - 80°c (set using keys 4 - 5). pressing the
OK
key allows the temperature set to be displayed; this can be
modified using the
OK
or
OK
keys.
The change must be confirmed by pressing the key
OK
.
pUmp OperatIOn
The pump activates water circulation when the t° of the water inside the stove reaches approx. 60°c. As the pump always functions above 60°,
an always open heating area is recommended to make product functioning homogenous, preventing overheating blocks. normally this area
is defined “Safety zone”.
rOOm temperatUre (
in the models envisioned)
IT IS possible to activate/deactivate the front ventilation and control the room temperature via the room probe (integrated in the handheld
device). (See "
ventiLation
" chapter in the following pages.)
BUrn pOt cleanInG
during the working phase, the stove has an internal timer, which after a pre-set period of time cleans the burn pot.
This phase is shown on the display, it interrupts pellet loading and increases the fumes exhaust motor for a determined period of time. When
the cleaning phase is finished, the stove will re-start automatically and continue the working phase, returning to the selected power level.
mOdUlatIOn and h-OFF
As the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum power. If the
temperature increases beyond the set point, it will automatically switch off indicating
h-OFF
and will automatically go back on when the
temperature drops below the set point.
SwItch-OFF
press the
OK
key for three seconds.
once this operation has been performed, the appliance automatically enters the switch-off phase, blocking the supply of pellets.
the flue gas exhaust motor and the hot air flow motor will remain on until the stove temperature has dropped below the default
parameters.
re-IGnItIOn
The stove can only be re-ignited automatically or manually when the cooling cycle conditions and the preset timer have been satisfied.
22