addItIOnal FUnctIOnS
cOmFOrt
This mode reduces the air flow speed, favouring the silent operation of the stove.
To activate, press the key
until
appears on the display.
To deactivate, press the key
until disappear on the display.
Once the cOmFOrt FUnctIOn IS actIvated, the StOve wIll alwayS USe redUced FrOnt aIr FlOw.
z1 and z2 dUctInG wIll remaIn Independent.
delta t
This function allows the hysteresis to be configured for stove switch-off
delTa T off (
set tempe delta T oFF hysteresis
)
and for stove
ignition (set tempe delta T on hysteresis) if it is not managed by an external thermostat.
The
delta T On/OFF
range is:
OFF - 0.5 - 5.5°C
SettInGS
SeT clocK
xx:xx - dd/mm/yy
date and time setting
lAnguAge
ita-ing-fra-ted-spa
language setting
dISplAY
display regulation
STAnd-BY
on/off
enables or disables the STAnd-BY FuncTIon
delTA T
oFF - 0.5 - 5.5°c
delTA T on/oFF regulation
NB: the DELTA T function will be displayed only when Stand-by is active (ON).
The calibration procedure is as follows:
go to the menu and select "TecHnIc SeT”.
configure the "F4" access key. - "AdJ SondA Tel-"
use the
OK
or
OK
keys to adjust the room temperature calibration as desired.
press the
OK
key to save and exit.
handheld rOOm SenSOr calIBratIOn
This mode allows the room temperature detected by the handheld to be calibrated. To ensure correct calibration, it is recommended to
position the handheld in a room with a constant temperature and wait for at least a couple of hours.
22