background image

DAHIANA - DAHIANA PLUS

C

B

A

F

F

F

(ONL

Y D

AHIANA PL

US)

D

A

E

D

C

F

F

(ONL

Y D

AHIANA PL

US)

F

C

32

ENGLISH

THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES.

a

Fumes motor (dismantle and clean the smoke duct and "T"), new seal where required

b

Gaskets, pellet hopper, inspections, ash drawer and door (replace and apply silicone where indicated)

C

Combustion chamber and heat exchanger (full cleaning) including ignition plug pipe

d

Hopper (complete emptying and cleaning)

e

Check the air intake pipe and check/clean the mechanical pressure switch

f

Remove the ambient air fan and remove any dust and pellet residue.

TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE: 

WWW.LANORDICA-EXTRAFLAME.COM

Summary of Contents for 001284000

Page 1: ...MADE IN ITALY design production DAHIANA DAHIANA plus TEOREMA 004280386 Rev 000 UK pellet stoves USER MANUAL...

Page 2: ...2 ENGLISH...

Page 3: ...the chrono 24 Settings 26 Display 26 stand by 26 OPERATION with additional thermostat optional 26 Additional thermostat 27 Additional thermostat installation 27 delta t 27 First Load 27 reset 27 Addit...

Page 4: ...OIRE Avant de bouger le po le faire attention lever les c ramiques indiqu es pour viter des d g ts OBVEZNA POZORNOST Prije pomicanja pe i uklonite ozna ene plo ice kako biste izbjegli o te enja VORSIC...

Page 5: ...TEOREMA 5 ENGLISH...

Page 6: ...well as the instructions contained in this manual The Manufacturer cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is in...

Page 7: ...ply cable so that it does not come into contact with hot parts ofthe appliance The power supply plug must be accessible after installation Do not close or reducethe dimensions ofthe airingvents in the...

Page 8: ...uid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICALLY THANKS TO THE TIMER OR REMOTELY USING THE DEDICATED APPLICATIONS IT IS STRICTLY...

Page 9: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can als...

Page 10: ...tion If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the building If the smoke duct is...

Page 11: ...mbient air outlet D Pellet hopper H Bulb thermostat reactivation B Access to combustion chamber and ash drawer E Combustion air inlet I On Off fuse 230V power supply C Upper fumes exhaust F Rear fumes...

Page 12: ...etails A Access to combustion chamber and ash drawer D Bulb thermostat reactivation G On Off fuse 230V power supply B Pellet hopper E Combustion air inlet H Ambient probe C Ambient air outlet F Rear f...

Page 13: ...ustion chamber and ash drawer D Combustion air inlet H Ambient probe B Pellet hopper E Rear fumes exhaust I Additional thermostat input Ducting additional thermostat input F Bulb thermostat reactivati...

Page 14: ...e operation At this point simply set the desired temperature on the thermostat the thermostat will command the operation of the second motor when the temperature has not been reached contact closed th...

Page 15: ...ration will cause the display to show the following CLOSE HOPPER STOVE DOOR This indication means that you have 60 seconds to close the hatch door and the pellet lid After the 60 seconds during igniti...

Page 16: ...be cured to obtain a sufficient heat yield THE USE OF POOR QUALITY PELLETS OR ANY OTHER MATERIAL WILL COMPROMISE STOVE FUNCTIONS VOIDING THE WARRANTY AND RELEASING THE MANUFACTURER OF LIABILITY Do no...

Page 17: ...On off stove hold for 3 seconds 9 Degrees Celsius Fahrenheit 4 Set power 10 Press the button once to enable or disable the chrono 5 Set switch off delay The button allows to set the switch off delay F...

Page 18: ...gnal receiver Handle the remote control with care When it is not being used place it on the special base supplied The remote control must not be left in a place where it is exposed to direct sunlight...

Page 19: ...t the contact of the external additional thermostat is closed Open contact the contact of the external additional thermostat is open Icon visible only if SET THERMOSTAT is set to LOW TA WI FI BT STBY...

Page 20: ...recommended to Ventilate the room well If present remove any majolica or natural stone parts from the top of the product Activate the product at the maximum power and temperature Avoid remaining in t...

Page 21: ...key 6 Select the language using keys 4 or 5 Press key 6 to confirm and key 1 to scroll back through the menus until the initial page Degrees This menu allows you to set the unit of measure for the te...

Page 22: ...tion LOW TA hot If the Set Thermostat is LOW TA set under the 7 threshold temperature checking is entrusted to the additional thermostat contact thus bypassing the on board temperature probe If the co...

Page 23: ...RANGE IF THE FIRST TWO ARE INSUFFICIENT Controls procedure Press key 6 Press key 3 until easy setup appears and confirm by pressing key 6 Use keys 4 5 to set the range Press key 6 to confirm and key...

Page 24: ...T Set thermostat PRG3 Power prg3 1 5 Set power PRG3 prg4 Start prg4 OFF 00 00 Ignition time PRG4 Stop prg4 OFF 00 00 Switch off time PRG4 Monday Sunday On off Enable disable days PRG4 Set prg4 LOW TA...

Page 25: ...0 23 00 08 00 16 30 t 22 18 2 1 25 ENGLISH Time slot 1 start 02 00 stop 23 00 power 3 set thermostat 22 C Time slot 2 start 08 00 stop 16 30 power 1 set thermostat 18 C stove operation Time slot Set p...

Page 26: ...STAND BY function is active ON if the room temperature exceeds the value of the Set Thermostat DELTA T OFF then the stove will switch off after a preset delay displaying STAND BY When the room temper...

Page 27: ...ground equal to 1 50 m Stove operation with the external thermostat connected in the TA clamp may differ depending on whether or not the STAND BY function is enabled Additional thermostat installation...

Page 28: ...function allows you to lock the display keys similar to mobile phones With the function active each time a key is pressed the message keys locked will appear To lock the keypad press keys 1 and 5 simu...

Page 29: ...eaning the ceramic glass Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simply use a...

Page 30: ...rom the burn pot slot ignition plug pipe holder and combustion chamber Clear clean all the holes in the burn pot Re position the burn pot in its slot and push it towards the fire wall NOTE Use a suita...

Page 31: ...y require subsequent technical assistance Requests for routine maintenance are not covered by the warranty GASKETS pellet hopper lid DOOR ASH DRAWER AND BURN POT INSPECTION OF SMOKE DUCTS The gaskets...

Page 32: ...r inspections ash drawer and door replace and apply silicone where indicated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleaning...

Page 33: ...licone where indicated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleaning E Check the air intake pipe and check clean the mechan...

Page 34: ...On indicates the presence of an alarm The alarm can only be reset if the fumes motor has stopped and 15 minutes have passed since the alarm was displayed by pressing key 1 for 3 seconds Fumes motor f...

Page 35: ...bility to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guar...

Page 36: ...aults in the electrical insulation This can cause electric shocks Installations not complying with the regulations in force as well as incorrect use and failure to comply with the maintenance schedule...

Page 37: ...37 ENGLISH...

Page 38: ...38 ENGLISH...

Page 39: ...39 ENGLISH...

Page 40: ...o extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary...

Reviews: