Extra M-575E User Manual Download Page 3

Extra 575 user manual                                             

Entar Professional Limited 

3

INTRODUCTION 

 

MAIN FEATURES 

 

540°pan and 270° tilt at 8/16 bit   

DMX channels: 13 

Lamp: Discharge lamp 575W, double ended (optional) 

Power consumption: 660W 

Dimmer: Smooth mechanical dimming 0-100% 

Strobe: 1~10 f.p.s. 

Prism: Rotating in both directions, three faces prism 

Color: 8 plus open white with rainbow effect 

Rotating gobo: 6 plus open white 

Focus: Motorized 

Speed: pan and tilt speed adjustment 

Pan and tilt position correction 

 
 

 

SETUP 

 

UNPACKING 

The Extra 575 comes with: 

User manual 

Power cable 

2x XLR connectors 

Lamp and clamps are optional (Please contact your dealer for more information) 

 

AC POWER 

Warning! 

For protection from electric shock, the fixture must be grounded (earthed). The power supply 

shall have overload and ground-fault protection. 

 

RIGGING OR MOUNTING THE EXTRA 575 

Warning! 

Attach an approved safety cable to the attachment point provided in the base. Never use the 

carrying handles for secondary attachment. Always use an approved safety cable. 

 

CONNECTING THE SERIAL DATA LINK 

 

The Extra 575 has locking 3-pin data input and output sockets that are wired for use with DMX devices 

with pin 1 to shield, pin 2 to cold(-) and pin 3 to hot(+). 

1.  Connect the controller’s output to the fixture’s data input. 

2.  Connect the output of the fixture closest to the controller to the input of the next fixture. If connecting 

a fixture with pin 3 hot to a fixture with pin 3 cold, use a phase-reversing adaptor. 

3.  To terminate the link, insert a male 120

 XLR termination plug in the output of the last fixture. 

 

Summary of Contents for M-575E

Page 1: ...Extra 575 user manual Entar Professional Limited 1 EXTRA 575 M 575E USER MANUAL ...

Page 2: ...al to a qualified technician PROTECTION FROM UV RADIATION AND LMP EXPLOSION Never operate the fixture with missing or damaged lenses and or covers When replacing the lamp allow the fixture to cool for at least 15 minutes before opening the fixture of removing the lamp Protect your hands and eyes with gloves and safety glasses Do not stare directly into the light Never look at an exposed lamp while...

Page 3: ...electric shock the fixture must be grounded earthed The power supply shall have overload and ground fault protection RIGGING OR MOUNTING THE EXTRA 575 Warning Attach an approved safety cable to the attachment point provided in the base Never use the carrying handles for secondary attachment Always use an approved safety cable CONNECTING THE SERIAL DATA LINK The Extra 575 has locking 3 pin data inp...

Page 4: ...tter is used terminate each branch of the link CONTROL PANEL MENU NAVIGATION The DMX address is displayed after the fixture resets To enter the menu press mode Use the up and down keys to select an option SETTING THE DMX MODE 1 Apply power to the Extra 575 Press mode to enter the Addr mode 2 Select a DMX starting address by using the up and down keys 3 Store the DMX starting address by pressing th...

Page 5: ...econds for reset the fixture Shutter open 7 0 255 Dimming Dark Æ bright 8 0 13 14 28 29 41 42 55 56 69 70 88 89 97 98 111 112 127 128 191 192 255 Color White Blue Purple Pink Red Green Yellow L blue Orange Continuous rotation CCW slow fast CW slow fast 9 0 17 18 35 36 53 54 71 72 89 90 107 108 127 128 191 192 255 Gobo selection Open gobo Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Continuous scroll ...

Page 6: ...tra 575 user manual Entar Professional Limited 6 11 0 127 128 255 Prism Prism off Prism on 12 0 8 9 119 120 231 232 255 Prism rotate Still CCW slow fast CW slow fast Macro 13 0 255 Focus Infinity Æ close ...

Reviews: