SAFETY INFORMATION 

 

PROTECTION FROM ELECTRIC SHOCK 

Warning!  

This product is for professional use only. It is not for household or residential use. 

This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet 

radiation, lamp explosion, and falls. Read this manual before powering or installing the fixture, follow the 

safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you 

have any question about how to use this fixture safely, please contact your Entar dealer. 

 

Warning!  

Always disconnect from mains supply before replacing the lamp. 

Disconnect the fixture from AC power before removing or installing the lamp, fuse, or any part, and when 

not in use. 

Always ground (earth) the fixture electrically. 

Use only a source of AC power that complies with local building and electrical codes and has both 

overload and ground-fault protection. 

Do not expose the fixture in rain and moisture. 

Refer any service operation not described in this manual to a qualified technician. 

 

PROTECTION FROM UV RADIATION AND LMP EXPLOSION 

Never operate the fixture with missing or damaged lenses and/or covers. 

When replacing the lamp, allow the fixture to cool for at least 15 minutes before opening the fixture of 

removing the lamp. Protect your hands and eyes with gloves and safety glasses. 

Do not stare directly into the light. Never look at an exposed lamp while it is lit. 

Replace the lamp if it becomes defective or worn out, or before usage exceeds the maximum service life. 

 

PROTECTION FROM BURNS AND FIRE 

Danger!   

Intense heat. Avoid contact by persons and materials. 

The exterior of the fixture can get very hot – up to 120

°

C. Allow the fixture to cool for at least 45 

minutes before handling. 

 

 

 

Prolonged exposure to unshielded lamp can cause eye and skin burns. 

Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of 

the specified type and rating. 

Keep all combustible materials (for example fabric, wood, paper) at least 1 meter away from the fixture. 

Keep flammable materials well away from the fixture. 

Do not illuminate surfaces within 3 meters (10 feet) of the fixture. 

Provide a minimum clearance of 0.1 meters around fans and air vents. 

Never place filters or other materials over the lens. 

 

 

 

 

Summary of Contents for M-575E

Page 1: ...Extra 575 user manual Entar Professional Limited 1 EXTRA 575 M 575E USER MANUAL ...

Page 2: ...al to a qualified technician PROTECTION FROM UV RADIATION AND LMP EXPLOSION Never operate the fixture with missing or damaged lenses and or covers When replacing the lamp allow the fixture to cool for at least 15 minutes before opening the fixture of removing the lamp Protect your hands and eyes with gloves and safety glasses Do not stare directly into the light Never look at an exposed lamp while...

Page 3: ...electric shock the fixture must be grounded earthed The power supply shall have overload and ground fault protection RIGGING OR MOUNTING THE EXTRA 575 Warning Attach an approved safety cable to the attachment point provided in the base Never use the carrying handles for secondary attachment Always use an approved safety cable CONNECTING THE SERIAL DATA LINK The Extra 575 has locking 3 pin data inp...

Page 4: ...tter is used terminate each branch of the link CONTROL PANEL MENU NAVIGATION The DMX address is displayed after the fixture resets To enter the menu press mode Use the up and down keys to select an option SETTING THE DMX MODE 1 Apply power to the Extra 575 Press mode to enter the Addr mode 2 Select a DMX starting address by using the up and down keys 3 Store the DMX starting address by pressing th...

Page 5: ...econds for reset the fixture Shutter open 7 0 255 Dimming Dark Æ bright 8 0 13 14 28 29 41 42 55 56 69 70 88 89 97 98 111 112 127 128 191 192 255 Color White Blue Purple Pink Red Green Yellow L blue Orange Continuous rotation CCW slow fast CW slow fast 9 0 17 18 35 36 53 54 71 72 89 90 107 108 127 128 191 192 255 Gobo selection Open gobo Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Continuous scroll ...

Page 6: ...tra 575 user manual Entar Professional Limited 6 11 0 127 128 255 Prism Prism off Prism on 12 0 8 9 119 120 231 232 255 Prism rotate Still CCW slow fast CW slow fast Macro 13 0 255 Focus Infinity Æ close ...

Reviews: