PROGRAMMING MODE DEFAULT MODE
Connect the 12 V ~ or 12 V power supply
Start up the system
Time-out
is saved
press the relay time-out
(2 digits between 01 and 99)
e.g. : 05 = 5 seconds
00 = on/off
by default = 5 seconds
+ press
The door is open
(The green LED lights up)
or
The keyboard beeps 4 times = error
Enter the default relay code =
(12345678) + press
RESET:
Press this key (and hold down during the entire procedure). Switch
off the power supply immediately. Switch the power supply back on, release
after 6 beeps.
The red LED lights up
Enter the default master code = (8 x
the digit 1) + press
press 52 + press
Relay time-out
Relay code
≠
Master code
= Melody
press 50 + press
Reconfigure by default
The system is reconfigured
by default