background image

VT10   V2.0  08/06 

Introduction 

Congratulations on your purchase of the Extech VT10 Multifunction Voltage Tester. The 
VT10 measures AC Voltage to 600V and DC Voltage to 400V with LED indicators, and 
LEDs for positive and negative polarity. Additional features include audible continuity 
beeper, low impedance mode for eliminating phantom voltages, and a built-in flashlight 
to illuminate test connections during measurements. This meter is shipped fully tested 
and with proper use will provide years of reliable service. 
 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user 
must refer to the manual for further information. 
 
This symbol, adjacent to a terminal, indicates that, under normal use, 
hazardous voltages may be present 
 
Double insulation

 

 

 

Safety Precautions 

1. 

Improper use of this meter can cause damage, shock, injury or death. Read and 

understand this manual before use. 

2. 

Ensure that any covers or battery doors are properly closed and secured before use. 

3. 

Inspect the condition of the test leads and the meter itself for any damage before 

use. 

4. 

Do not exceed the rated input limits. 

5. 

Use great care when taking measurements greater than 25VAC rms or 35VDC. 

These voltages are considered a shock hazard. 

6. 

Discharge capacitors and remove power from the DUT before Continuity tests. 

7. 

Remove the batteries from the meter if the meter is to be stored for long periods. 

8. 

Voltage measurement results on electrical outlets can be misleading because of the 

difficulty in making a proper connection to the electrical contacts. 

9. 

NEVER

 apply voltage to the meter that exceeds the specified maximum: 

Input Protection Limits 

Function Maximum 

Input 

VAC, VDC, 
Continuity 

600VAC: 30 second max 
400VDC: 30 second max 

10. 

USE EXTREME CAUTION

 when working with high voltages. 

11. 

ALWAYS

 discharge filter capacitors in power supplies and disconnect the power 

when making continuity tests. 

12. 

ALWAYS

 disconnect the test leads before opening the cover to replace the battery. 

13. 

NEVER

 operate the meter unless the battery cover is in place and fastened 

securely. 

 
 

Summary of Contents for VT10

Page 1: ...ton Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com Back to the Extech VT10 Product Info Page Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com ...

Page 2: ...vers or battery doors are properly closed and secured before use 3 Inspect the condition of the test leads and the meter itself for any damage before use 4 Do not exceed the rated input limits 5 Use great care when taking measurements greater than 25VAC rms or 35VDC These voltages are considered a shock hazard 6 Discharge capacitors and remove power from the DUT before Continuity tests 7 Remove th...

Page 3: ...ndicator 6 LED low impedance test indicator 7 LED DC V V polarity indicators 8 LED continuity indicator 9 LED AC DC voltage indicators 10 Low impedance button 11 Flashlight button 12 Battery cover 13 Low impedance button Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com ...

Page 4: ...ly the presence of voltage is detected Low Impedance Voltage Measurement Due to the lowered internal impedance capacitive voltage is suppressed so that the reading shows the actual voltage applied This can be used to quickly identify phantom voltages 1 Hold the two test tips on the measuring points to be tested 2 Press the two low impedance test buttons simultaneously 3 The Low Impedance LED will ...

Page 5: ... 208 240 277 480 600 DC 6 12 24 36 48 110 220 400 ACV frequency range 50 60Hz LED enable input voltage 4 5V AC DC Accuracy 30 to 0 of the indication Range selection Automatic Max measuring current 1 2mA 600VAC 1 0mA 400VDC Display delay LED indication 0 1s Input Impedance 1MΩ approx Continuity test Range 0 to 400kΩ guaranteed on 50kΩ 10µA test current Low impedance test 12 250VAC DC impedance 6kΩ ...

Reviews: