Specifications 

Display 

Backlit LCD 35 x 30mm (1.4 x 1.2“)

 

Light sensor 

Photo sensor with cosine correction filter 

Measurements 

Ultraviolet Light (UVA) 

UV sensor spectrum 

320 to 390 nm 

Input Overload Display 

“----“ 

Tripod mount 

On rear panel 

Power 

3 x 1.5V ‘AAA’ batteries

 

Power Consumption 

Approx. 5mA DC 

Automatic power off 

After approx. 10 minutes of inactivity 

Operating temperature 

0 to 50

o

C (32 to 122

o

F) 

Operating humidity 

80% RH max 

Dimensions/Weight 

141 x 58 x 25mm (5.5 x 2.3 x 1.0”) /160g (5.64oz)

 

Electrical Specifications (23±5

°

C) 

Ultraviolet

 

(UVA)

 

Unit 

Range 

Resolution 

Accuracy 

mW/cm

2

 

0 to 1.999 

0.001 

±(4% FS + 2dgt) 

2 to 20.00 

0.01 

 

 

Copyright 

©

 2017 FLIR Systems, Inc. 

All rights reserved including the right of reproduction in whole or in part in any form 

ISO-9001 Certified 

www.extech.com 

 

Summary of Contents for UV510

Page 1: ...USER MANUAL UV Light Meter Model UV510 Additional User Manual Translations available at www extech com ...

Page 2: ...Long wave 365nm ultraviolet irradiance measurements UVA Lightweight ergonomic design Safety Please read the entire User Manual and Quick Start before operating this device Use the meter only as specified and do not attempt to service or open the meter housing Do not allow children to handle the meter or the protective cover Please dispose of batteries and meter responsibly and in accordance with a...

Page 3: ...n 6 Zero button 7 SET and button 8 Record button max min 9 Hold button 10 Light sensor cover Note Battery compartment and tripod mount on rear of meter LCD Description 1 Primary Display 2 MAX MIN Record Icon 3 MAX Icon 4 MIN Icon 5 Display Hold Icon 6 Battery Indicator 7 Auto Power OFF 8 Unit of measure mW cm2 9 Selected Range Display ...

Page 4: ...0 00mW cm2 the lower display will show the selected range Zero Function To zero the display place the protective light cover over the UV sensor and press the ZERO button Data Hold Short press the H hold button to freeze or unfreeze a reading on the display Hold function is not operational while in record mode Backlight The LCD is equipped with backlighting for easier viewing especially in dimly li...

Page 5: ...operational in record mode Maintenance Battery Replacement 1 Power OFF the meter 2 Remove the flat head screw that secures the battery compartment at the back of the meter 3 Open the battery compartment and replace the 3 AAA 1 5V batteries observing correct polarity Re assemble the meter before use Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may ex...

Page 6: ...tion Approx 5mA DC Automatic power off After approx 10 minutes of inactivity Operating temperature 0 to 50o C 32 to 122o F Operating humidity 80 RH max Dimensions Weight 141 x 58 x 25mm 5 5 x 2 3 x 1 0 160g 5 64oz Electrical Specifications 23 5 C Ultraviolet UVA Unit Range Resolution Accuracy mW cm2 0 to 1 999 0 001 4 FS 2dgt 2 to 20 00 0 01 Copyright 2017 FLIR Systems Inc All rights reserved incl...

Reviews: