background image

Version 3.1   1/06 

MAX Hold 

The MAX display indicates and holds the highest dB level measured 
since the meter was turned on or since the Max Reset button was 
pressed. The time and date of the max reading is also displayed. 

To clear the display and start a new measurement session, press the 
front panel MAX RESET button. If the measured level exceeds the 
maximum for the range selected the MAX display will indicate “OL” (overload). 

Programmable OFF/ON/AUTO time 

The meter is powered by 8 AA batteries or via an AC adaptor for permanent installations. 
Continuous battery life is approximately 240 hours (10 days). By programming the ON/OFF 
time, the battery life can be greatly extended (30 days assuming an 8 hour day). The 

ON

 

and 

OFF

 times are programmed as described in the initial configuration 

paragraph. The meter will operate continuously with the power switch in 
the ON position. The ON/OFF time will be controlled by the meter when 
the power switch is set to the AUTO position. 

Calibration 

The sound level meter should be calibrated on a regular basis 
to assure that the meter’s performance and microphone 
sensitivity has not change. Some operational directives 
require daily calibration checks (OSHA). Extech offers several 
acoustic calibrators to perform the calibration. 

1.  Set the meter to the 60 to 110dB or 80 to 130dB range. 

2.  Place the external calibrator over the Sound Level 

Monitor's microphone and turn the Calibrator on. 

3.  The meter should read close to the calibrator's dB output 

level. Typical Calibrator output levels are 94dB and 114dB. 

4.  If the meter is within ± 0.2 dB of the calibrator’s output, no 

adjustment is necessary. 

5.  Adjust the calibration pot on the rear of the meter to the 

proper level. 

 

 

Meter Placement 

The meter can be used Handheld, Wall mounted, Desk mounted or Tripod mounted. For 
wall mount operation, orient the microphone perpendicular to the wall to minimize the 
affect of acoustic reflections. For desk mounting, extend the rear legs and lock in place 
with the hinged locks. The tripod mounting nut is located on the bottom of the unit. 

 

 

 

 

 

 

Summary of Contents for SL130

Page 1: ... Type 2 Sound Level Meter Standards Settable High Limit with large bright High Low indication and Alarm Output Wall or Desk mountable Extra large LCD display with bargraph Maximum level display with time stamp Optional alarm kit drives remote over limit indicators ...

Page 2: ...OFF time extends battery life to 30 days when programmed 8 hours per day The bright LED s are functional only when the AC power adaptor is used Careful use of this meter will provide years of reliable service Specifications Applicable standards Meets IEC 60651 1979 and ANSI S1 4 1983 Type 2 SLM standards Display 11 7 x 7 94cm 4 6 x 3 125 multifunction LCD Frequency bandwidth 31 5 Hz to 8 KHz Micro...

Page 3: ...utton Rear Control Panel 1 Range select switch 2 Time set buttons 3 Limit set buttons 4 Calibration adjustment 5 A C select button 6 F S select button Side Panel 1 Alert switch Green position 2 Alert switch Red Green position 3 Alert switch Red position 4 High Low Alarm switch 5 Remote Alarm output connector 6 AC adaptor connector Rear Panel 1 Tilt stand 2 Battery compartment 3 AC Adaptor connecto...

Page 4: ...just Time of day Hour Time of day Minutes Time of day AM PM 24 Hour Year Month Day Auto ON Hour Auto ON Minutes Auto OFF Hour Auto OFF Minute A C Frequency Weighting Change the Frequency Weighting by pressing the A C button The A or C icon will appear on the display With A weighting selected the frequency response of the meter is similar to the response of the human ear A weighting is commonly use...

Page 5: ...play indication and output signal will remain active as long as the sound pressure level exceeds the set limit High Low LED Alert The four LEDs are used to alert users when a sound level either exceeds or goes below the Limit set point This feature is available only while the AC adaptor is used to power the meter It is disabled under battery power The LEDs will provide a steady or flashing colored...

Page 6: ... the power switch is set to the AUTO position Calibration The sound level meter should be calibrated on a regular basis to assure that the meter s performance and microphone sensitivity has not change Some operational directives require daily calibration checks OSHA Extech offers several acoustic calibrators to perform the calibration 1 Set the meter to the 60 to 110dB or 80 to 130dB range 2 Place...

Page 7: ...tension cable can then be plugged into the matching connectors Calibration should be performed after the cable is installed Alarm Output optional The alarm output drives the optional Remote Alarm Relay Module cable and relay when the LIMIT set point is exceeded The relay module can be used to power external warning signs QUIET signs or other indicating devices when the sound level is higher than t...

Page 8: ...t to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go t...