Specifications 

Function 

Range and Resolution 

Accuracy 

Humidity

 

0.0 to 100.0% RH 

±3% RH (10 to 90%)

@ 23

°

Temperature (air) 

-4.0 to 122.0

o

F (-20 to 50

o

C) ±1.8

o

F (±1

o

C) 

Temperature (external) T1, T2 

-328 to 2250

o

F (-200 to 1370

o

C)

±0.3% rdg or 

±(1.8

o

F)1

o

Display  

Triple LCD 

Sensor Type   

Humidity: Precision capacitance sensor 

Internal Temperature: Thermistor 

External Temperature: K-Type Thermocouple 

Response Time 

60 seconds typical 

Dew Point 

-90.4 to 122.0

o

F (-68 to 50

o

C) (calculated from RH and Air 

temperature measurements) 

Wet Bulb 

-6.88 to 122.0

o

F (-21.6 to 50

o

C) (calculated from RH and Air 

temperature measurements)

 

Low Battery Indicator 

Yes 

Overrange Indicator 

E2 (air) E5 (T1), E8 (T2) 

Underrange Indicator 

E3 (air),

 

E6 (T1), E9 (T2) 

Operating Conditions

 

-4 to 122

o

F (-20 to 50

o

C); < 99% RH non-condensing 

Storage Conditions

 

-40 to 185

o

F (-40 to 85

o

C); <99% RH non-condensing 

Power Supply 

4 x 1.5V ‘AAA’ batteries 

Battery Life 

 

Approx. 300 hours 

Dimensions / Weight

 

9 x 2.2 x 1.7” (230 x 57 x 44mm); 5.3 oz. (153g) 

 

Meter Description 

1. 

Humidity Sensor & Air Temperature Sensor 

2. 

Triple LCD Display 

3. 

On/Off; Set Mode 

4. 

Min/Max/Average; Reset Min/Max 

5. 

Air, T1, Air-T1, Dew Point 

6. 

T1 probe input 

7. 

T2 probe input 

8. 

T1-T2, T2, T1-Dew Point, Wet Bulb 

9. 

Store Current Reading; Backlight 

10.  Hold; Recall Mode 

11. RS232 

port 

 

 

Note: The battery compartment is located  

on the rear of the instrument 

Summary of Contents for RH355

Page 1: ...perature T1 T2 Air T1 T1 DP Humidity Air Temperature Dew Point and Wet Bulb Advanced features include built in memory and recall of up to 99 data points Min MAX Average readings from the captured data...

Page 2: ...lculated from RH and Air temperature measurements Low Battery Indicator Yes Overrange Indicator E2 air E5 T1 E8 T2 Underrange Indicator E3 air E6 T1 E9 T2 Operating Conditions 4 to 122 o F 20 to 50 o...

Page 3: ...ween Air temperature T1 temperature Air T1 and DP Dew Point 7 Pressing the T2 WB button toggles the lower left display between WB Wet Bulb T1 T2 T2 and T1 DP Dew Point Selecting temperature units of m...

Page 4: ...enter auto power off settings Press the MEM button to select non sleep n or 2 5 10 20 40 and 60 minutes autosleep Press T2 WB to confirm the selection Manual Datalogging Manual datalogging allows the...

Page 5: ...reading may vary depending on operating temperature will flash on the LCD screen After 30 minutes the flashing will stop to indicate that the 33 calibration is complete Note To exit from the calibrati...

Page 6: ...x xC Hxx x Txxx xC Txxx xC Txxxx xC Txxxx xCLRCCRLF or Txxx xF Hxx x Txxx xF Txxx xF Txxxx xF Txxxx xFLRCCRLF Where The 1 st value is Air Temperature the 2 nd value is Humidity the 3 rd value is Dew P...

Page 7: ...ee of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service...

Reviews: