Model PH220 Version 3.1 11/2005 

Meter Description 

 

1. 

Battery Compartment (under holster) 

2. Rubber 

Holster 

3. LCD 

Display 

4. Function 

buttons 

5. Electrode 

input 

 

 

 

 

 

 

 

 

Basic Display Description 

 

1. Measurement 

value 

2. Battery 

status 

3. 

Units of measure 

4. Temperature 

units 

5. Solution 

temperature 

 

 

 

 
 

Note that there are other more specialized displays that appear on the LCD that have not 
been included in this basic operation display description. Other display icons are used and 
are discussed in the appropriate sections of this manual. 

 

Order of Operations 

1.  Calibrate the instrument as described later in this manual. 

2.  Determine the test type (pH or ORP) and carefully follow the directions for the desired 

test. 

3.  Configure the meter to display in the desired units of measure for temperature (

o

C or 

o

F). This is included as a step in the pH measurement instructions.  

4.  Pay close attention to detail, step by step instructions, and electrode cleaning/rinsing 

recommendations. Slight deviations in test procedures and test habits can have a 
significant effect on test results. 

7.00

1

5

4

3

2

1

2

3

4

5

Summary of Contents for PH220A

Page 1: ...evice with tactile push buttons is battery operated and ideal for field use The PH220 simultaneously displays pH and temperature The rubber holster which protects the meter has a magnetic backing for...

Page 2: ...simultaneous pH and temperature readings Over range or open indication Displays HHH for over range or open input conditions Displays LLL for under range pH Calibration points 4 00 7 00 10 00 1 2 or 3...

Page 3: ...play icons are used and are discussed in the appropriate sections of this manual Order of Operations 1 Calibrate the instrument as described later in this manual 2 Determine the test type pH or ORP an...

Page 4: ...nction does not require calibration pH Calibration Procedure 1 Place the electrode into a 7 00 pH buffer solution Press and hold the CAL button until CAL appears in the display 2 The instrument automa...

Page 5: ...g the on off button Wait for the self test SLF tSt to finish 4 Use the MODE button to select mV mode The display will reflect the unit of measure 5 Place the electrode into a sample solution When the...

Page 6: ...time the recall mode is accessed 3 While in the RECALL mode use the STORE RECALL button to scroll through the stored readings The most recent readings will show first LAST IN FIRST OUT 4 Press and ho...

Page 7: ...it over the top of the meter ensure that the electrode is disconnected 3 Pry the battery compartment up from the top of the meter using a screwdriver or coin at one of the two indentations see diagra...

Page 8: ...ine measurement Soak in 0 1 M HCL overnight Deteriorated Gel layer Replace electrode Protein coating on electrode surface Soak in 1 gm Pepsin dissolved in 100ml of 0 1 m HCL for 30 minutes or as neede...

Page 9: ...o sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authori...