background image

MA145

en

GB_V1.1

   

5/15

 

5

Operation

 

CAUTIONS

 

 

Read

 

and

 

understand

 

all

 

of

 

the

 

Safety

 

statements

 

listed

 

in

 

the

 

safety

 

section

 

of

 

this

 

manual

 

prior

 

to

 

use.

 

Powering

 

the

 

Meter

 

1.

 

Press

 

the

 

Power

Backlight

 

button

 

to

 

power

 

the

 

meter.

 

Check

 

the

 

batteries

 

if

 

the

 

unit

 

fails

 

to

 

power

 

ON.

 

2.

 

Press

 

and

 

hold

 

the

 

Power

 

button

 

for

 

more

 

than

 

2

 

seconds

 

to

 

power

 

OFF

 

the

 

meter.

 

3.

 

The

 

meter

 

has

 

an

 

Auto

 

Power

 

OFF

 

feature

 

(APO)

 

where

 

the

 

meter

 

switches

 

OFF

 

after

 

20

 

minutes

 

of

 

inactivity.

 

To

 

disable

 

APO,

 

refer

 

to

 

the

 

next

 

section.

 

Note:

 

The

 

meter

 

displays

 

the

 

battery

 

capacity

 

when

 

powering

 

up.

 

Disable

 

Auto

 

Power

 

OFF

 

The

 

meter

 

will

 

auto

 

power

 

OFF

 

after

 

20

 

minutes

 

of

 

inactivity.

 

To

 

defeat

 

this

 

feature,

 

follow

 

the

 

steps

 

below.

 

1.

 

With

 

the

 

meter

 

OFF,

 

press

 

and

 

hold

 

the

 

‘V’

 

button

 

and,

 

while

 

continuing

 

to

 

hold

 

the

 

‘V’

 

button,

 

press

 

the

 

power

 

button.

 

2.

 

The

 

display

 

will

 

show

 

AOFF

.

 

3.

 

Release

 

all

 

of

 

the

 

buttons.

 

4.

 

The

 

Auto

 

Power

 

OFF

 

function

 

will

 

now

 

be

 

disabled

 

until

 

the

 

next

 

cycle

 

of

 

power.

   

Display

 

Backlight

 

With

 

the

 

meter

 

powered

 

ON,

 

press

 

the

 

backlight

 

button

 

to

 

switch

 

the

 

backlight

 

ON

 

or

 

OFF.

 

Note

 

that

 

excessive

 

use

 

of

 

the

 

backlight

 

will

 

shorten

 

the

 

battery

 

life.

  

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for MA145

Page 1: ...USER GUIDE True RMS 300A AC DC Mini Clamp Meter with Non Contact Voltage Detector Model MA145 www GlobalTestSupply com nd Quality Products Online at sales GlobalTestSupply co...

Page 2: ...protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to be carried out could be accessible If the equipment is used in a manner not specified by the m...

Page 3: ...f OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electronic...

Page 4: ...rement 8 Amperes current 9 Main Display area 10 Battery status icon 11 Minus negative sign 12 Non Contact Volt Detect icons Control Button Description Press for 2 seconds to access In rush Current mod...

Page 5: ...ote The meter displays the battery capacity when powering up Disable Auto Power OFF The meter will auto power OFF after 20 minutes of inactivity To defeat this feature follow the steps below 1 With th...

Page 6: ...ton to toggle DC and AC 3 When in AUTO mode the display shows the AUTO icon in the upper left corner 4 The meter display will show AC or DC on the right side of the display 5 When in DC Current mode p...

Page 7: ...4 To exit the Inrush Current mode press the INRUSH button again momentarily The INRUSH icon will switch OFF TIME CURRENT 0A Start Stop Current Detection Threshold Measured Inrush Current 100ms Sample...

Page 8: ...ct Voltage Detect mode 2 Note the voltage detection display icons as shown in the Description section of this guide 3 Place the meter near a source of electrical energy The tip of the clamp offers the...

Page 9: ...rect polarity 4 Re assemble the meter before use 5 Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak never mix battery types install new...

Page 10: ...aracteristic 24db per octave approximately Function Range Resolution Accuracy of reading Inrush Current 300 0 A 0 1 3 5 5 digits Integration time 100ms Trigger current threshold 5A Voltage Detector 80...

Page 11: ...accuracy C 18 C 64 5 F 28 C 82 4 F Operating Altitude 2000m 6562ft Battery power 2 LR 44 1 5V batteries battery life 20 hours typical Weight 140g 4 9 oz Dimensions 60 x 147 x 31 5mm 2 4 x 5 8 x 1 2 S...

Reviews: