Specifications

 

ELECTRICAL

 

SPECIFICATIONS

 

Function

 

Range

 

Resolution

 

Accuracy

 

(of

 

reading)

 

 

50~100Hz

 

100~400Hz

 

AC

 

Current

 

60.00

 

A

 

0.01

  

±

 

(1.5%

 

+

 

25

 

digits)

 

<

 

3A

 

±

 

(1.5%

 

+

 

5

 

digits)

 ≥ 

3A

 

±

 

(2.5%

 

+

 

25

 

digits)

 

<

 

3A

 

±

 

(2.5%

 

+

 

5

 

digits)

 ≥

 

3A

 

300.0

 

A

 

0.1

  

Function

 

Range

 

Resolution

 

Accuracy

 

(of

 

reading)

 

DC

 

Current

 

60.00

 

A

 

(1)

 

0.01

  

±

 

(1.5%

 

+

 

10

 

digits)

 

(2)

 

300.0

 

A

 

0.1

  

±

 

(1.5%

 

+

 

5

 

digits)

 

(1)

 

 

<

 

0.3A

 

variation

 

when

 

measuring

 

in

 

varying

 

directions

 

(2)

 

Add

 

10d

 

to

 

accuracy

 

in

 

AUTO

 

AC/DC

 

sense

 

mode

 

Function

 

Range

 

Resolution

 

Accuracy

 

(of

 

reading)

 

50Hz/60Hz

 

Low

 

Pass

 

Filter

 

(LPF)

 

60.00

 

A

 

0.01

  

±

 

(3.5%

 

+

 

25

 

digits)

 

<

 

3A

 

±

 

(3.5%

 

+

 

5

 

digits)

 ≥ 

3A

  

300.0

 

A

 

0.1

  

Cut

off

 

frequency

 

(

3db):

 

160Hz

 

(approximately)

 

Attenuation

 

characteristic:

 ‐

24db

 

per

 

octave

 

(approximately)

Function

 

Range

 

Resolution

 

Accuracy

 

(of

 

reading)

 

Inrush

 

Current

 

300.0

 

A

 

0.1

  

±

 

(3.5%

 

+

 

5

 

digits)

 

Integration

 

time:

 

100ms

 

Trigger

 

current

 

(threshold):

 

5A

 

Voltage

 

Detector

 

80V~600VAC

 

n/a

 

n/a

  

The

 

tip

 

of

 

the

 

clamp

 

offers

 

the

 

optimum

 

sensitivity

 

Notes:

 

 

Clamp

 

position

 

error:

 

±1.5%

 

of

 

reading

 

 

Accuracy

 

is

 

given

 

as

 

±

 

(%

 

of

 

reading

 

+

 

least

 

significant

 

digit)

 

at

 

23C

 

±5C

 

with

 

relative

 

humidity

 

lower

 

than

 

80%.

 

Accuracy

 

is

 

specified

 

for

 

a

 

period

 

of

 

one

 

year

 

after

 

calibration.

 

 

ACA

 

specifications

 

are

 

for

 

AC

 

Coupled,

 

True

 

RMS.

 

For

 

square

 

wave

 

the

 

accuracy

 

for

 

>100Hz

 

is

 

unspecified.

 

For

 

non

sinusoidal

 

waveforms,

 

additional

 

accuracy

 

Crest

 

Factor

 

(C.F.)

 

considerations

 

exist

 

as

 

detailed

 

below:

 

Add

 

3.0%

 

for

 

C.F.

 

1.0~2.0

 

Add

 

5.0%

 

for

 

C.F.

 

2.0~2.5

 

Add

 

7.0%

 

for

 

C.F.

 

2.5~3.0

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for MA145

Page 1: ...USER GUIDE True RMS 300A AC DC Mini Clamp Meter with Non Contact Voltage Detector Model MA145 www GlobalTestSupply com nd Quality Products Online at sales GlobalTestSupply co...

Page 2: ...protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to be carried out could be accessible If the equipment is used in a manner not specified by the m...

Page 3: ...f OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electronic...

Page 4: ...rement 8 Amperes current 9 Main Display area 10 Battery status icon 11 Minus negative sign 12 Non Contact Volt Detect icons Control Button Description Press for 2 seconds to access In rush Current mod...

Page 5: ...ote The meter displays the battery capacity when powering up Disable Auto Power OFF The meter will auto power OFF after 20 minutes of inactivity To defeat this feature follow the steps below 1 With th...

Page 6: ...ton to toggle DC and AC 3 When in AUTO mode the display shows the AUTO icon in the upper left corner 4 The meter display will show AC or DC on the right side of the display 5 When in DC Current mode p...

Page 7: ...4 To exit the Inrush Current mode press the INRUSH button again momentarily The INRUSH icon will switch OFF TIME CURRENT 0A Start Stop Current Detection Threshold Measured Inrush Current 100ms Sample...

Page 8: ...ct Voltage Detect mode 2 Note the voltage detection display icons as shown in the Description section of this guide 3 Place the meter near a source of electrical energy The tip of the clamp offers the...

Page 9: ...rect polarity 4 Re assemble the meter before use 5 Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak never mix battery types install new...

Page 10: ...aracteristic 24db per octave approximately Function Range Resolution Accuracy of reading Inrush Current 300 0 A 0 1 3 5 5 digits Integration time 100ms Trigger current threshold 5A Voltage Detector 80...

Page 11: ...accuracy C 18 C 64 5 F 28 C 82 4 F Operating Altitude 2000m 6562ft Battery power 2 LR 44 1 5V batteries battery life 20 hours typical Weight 140g 4 9 oz Dimensions 60 x 147 x 31 5mm 2 4 x 5 8 x 1 2 S...

Reviews: