Safety
This symbol adjacent to another symbol, terminal or
operating device indicates that the operator must refer to an
explanation in the Operating Instructions to avoid personal
injury or damage to the meter.
This
WARNING
symbol indicates a potentially hazardous
situation, which if not avoided, could result in death or
serious injury.
This symbol indicates that a device is protected throughout
by double insulation or reinforced insulation.
This meter has been designed for safe use, but must be operated with caution.
The rules listed below must be carefully followed for safe operation.
1.
NEVER
apply voltage or current to the meter that exceeds the specified
maximum:
Input Protection Limits
Function Maximum
Input
V DC or V AC
600V DC/AC
µA AC/DC
200mA 500V
fast acting resettable fuse
Resistance, Diode Test,
Continuity Test
600V DC/AC
2.
USE EXTREME CAUTION
when working with voltages greater than 25VAC
or 35VDC. These voltages are considered a shock hazard.
3.
DO NOT
measure voltage if the voltage on the "COM" input jack exceeds
600V above earth ground.
4.
NEVER
connect the meter leads across a voltage source while the function
switch is in the current, resistance, or diode mode. Doing so can damage the
meter.
5.
ALWAYS
discharge filter capacitors in power supplies and disconnect the
power when making resistance, continuity or diode tests.
6.
ALWAYS
turn off the power and disconnect the test leads from the circuit
before opening the cover to replace the batteries.
7.
NEVER
operate the meter unless the battery cover is in place and fastened
securely.
Description
1. Non-contact ACV detector probe tip
2. Non-contact ACV indicator light
3. 3-3/4 digit (4000 count) LCD
4. Mode
switch
5. Flashlight
button
6. Function
switch
7. Battery
cover
8. Test
Leads
9. Hz/%Duty Cycle button
10. Flashlight
WARNING
1
2
3
4
5
6
7
8
9
10
www.burntec.com