DCP60

EU

DE

 

v1.4

   

9/13

 

8

Using

 

the

 

control

 

knobs

 

The

 

rotary

 

encoder

 

control

 

knobs

 

have

 

fine

 

and

 

coarse

 

tuning

 

with

 

‘clicking’

 

movement.

 

Push

 

the

 

knobs

 

to

 

toggle

 

between

 

coarse

 

and

 

fine

 

tuning,

 

notice

 

the

 

subtle

 

changes

 

in

 

brightness

 

of

 

the

 

related

 

LED.

 

Adjust

 

the

 

knobs

 

to

 

the

 

desired

 

values

 

by

 

using

 

coarse

 

and

 

then

 

fine

 

tuning.

 

The

 

display

 

will

 

resume

 

its

 

normal

 

brightness

 

after

 

few

 

seconds

 

to

 

confirm

 

an

 

adjustment.

 

Connecting

 

the

 

Power

 

Supply

 

and

 

running

 

a

 

test

 

1. 

Connect

 

the

 

equipment

 

under

 

test

 

to

 

the

 

power

 

supply.

 

Red

 

(+)

 

is

 

connected

 

to

 

the

 

positive

 

polarity

 

input

 

of

 

the

 

equipment

 

and

 

Black

 

(

)

 

is

 

connected

 

to

 

the

 

negative

 

polarity

 

input

 

of

 

the

 

equipment.

 

2. 

Switch

 

ON

 

the

 

power

 

supply

 

first;

 

the

 

panel

 

meter

 

&

 

green

 

CV

 

Indicator

 

should

 

illuminate.

 

3. 

Next,

 

switch

 

ON

 

the

 

equipment

 

under

 

test;

 

the

 

panel

 

meter

 

&

 

green

 

CV

 

Indicator

 

should

 

remain

 

lit

 

in

 

green.

 

4. 

Testing

 

can

 

now

 

begin.

 

5. 

When

 

finished,

 

switch

 

OFF

 

the

 

equipment

 

under

 

test

 

first

 

and

 

then

 

switch

 

off

 

the

 

power

 

supply.

 

 
 

Einstellen

 

des

 

Netzgeräts

 

im

 

Konstantstrom

Modus

 

(CC)

 

 

1. 

Stellen

 

Sie

 

den

 

Stromregler

 

auf

 

Minimum

 

2. 

Stellen

 

Sie

 

den

 

Spannungsregler

 

auf

 

Maximum

 

3. 

Schließen

 

Sie

 

die

 

Ausgangsleitungen

 

miteinander

 

kurz

 

4. 

Schalten

 

Sie

 

das

 

Netzgerät

 

ein

 

5. 

Drehen

 

Sie

 

den

 

Stromregler

 

auf,

 

bis

 

der

 

gewünschte

 

Stromwert

 

erreicht

 

ist.

 

6. 

Schalten

 

Sie

 

das

 

Netzgerät

 

aus

 

7. 

Lösen

 

Sie

 

die

 

Ausgangsleitungen

 

voneinander

 

 

Summary of Contents for DCP60

Page 1: ...USER GUIDE Model DCP60 and Model DCP60 220 Switching Mode DC Power Supplies 60V 10A Adjustable...

Page 2: ...nd can be performed without output spiking The Remote Control feature permits output ON OFF and Voltage Current adjustments The USB port offers PC connectivity for programming and running ramp cycles...

Page 3: ...ains 4 Refer all servicing to qualified service personnel only 5 Before replacing the AC fuse determine the cause and clear up the cause first 6 Replace the AC fuse with the same type and rating as th...

Page 4: ...Current Control Knob controls both the main and auxiliary output current limit 5 Power ON OFF Switch 6 Aux output terminal max 5A The total rated current Aux Main is 10A REAR PANEL 7 Haupt Ausgangskle...

Page 5: ...2 P3 available using the Recall Selection Switch 9 3 The preset values are factory set as shown in the table below 4 The user can change these output settings please refer to the next paragraph Recall...

Page 6: ...tory Default settings 1 Switch OFF the power supply 2 Push and hold both front panel voltage and current control knobs at the same time 3 Switch ON the power supply again 4 Release the front panel vol...

Page 7: ...ll perform a series of self tests when it is switched on The LED and other indicators on the front panel will illuminate in sequence When the cooling fan is being checked a high speed wind sound can b...

Page 8: ...uipment and Black is connected to the negative polarity input of the equipment 2 Switch ON the power supply first the panel meter green CV Indicator should illuminate 3 Next switch ON the equipment un...

Page 9: ...ote Socket Pin Assignment for external variable voltage source PIN FUNCTIONS REMARKS 1 Internal DC 5V Lower than 50mA 2 Voltage adjust 0 to 5V Externes VDC Signal 3 Current adjust 0 to 5V Externes VDC...

Page 10: ...istor 2 Voltage adjust Variable leg of resistor 3 Current adjust Variable leg of resistor 4 Ground Other end of resistor 5 Output OFF EIN Short to ground zum Ausschalten 6 N A 7 N A 8 N A Check the ou...

Page 11: ...5 to Pin 4 ground switches the output OFF When the output is OFF the C V C C LEDs will flash The present output voltage and current setting will be shown on the panel meter The user can adjust the out...

Page 12: ...execution of the installer file 8 When the Silicon Labs prompt appears select Install to load the necessary drivers onto your PC An older version of the drivers may already reside on your PC therefor...

Page 13: ...ormation 3 Voltage and Current setting panel Use this panel to set the output values and to switch the output On Off 4 Data handling panel Use this panel to save load and print data 5 External Timed P...

Page 14: ...ing 2 Current Output setting 3 Output ON OFF setting 4 SET confirm output values Directly type the value in the Voltage and Current fields or use the slider to set the Voltage and Current values and t...

Page 15: ...er t angeschlossen werden soll Stellen Sie mit dem Schieberegler die Datenlogger Abtastdauer Rate ein Stellen Sie den oberen Grenzwert der Ausgangsspannung UVL ein um Niederspannungsanwendungen zu sch...

Page 16: ...gswert erreicht ist Sobald der Schieberegler aktiv ist k nnen Sie die Pfeiltasten links und rechts der Tastatur zur Feineinstellung nutzen Stellen Sie die Dauer f r diesen Schritt ein wie in der Abbil...

Page 17: ...cher Die Fernsteuerung Vorbelegungsfunktion der PC Schnittstelle vereinfacht den langwierigen Eingabevorgang von Gruppen von Eintr gen Da alle Daten auf dem PC Monitor gleichzeitig dargestellt werden...

Page 18: ...er rechts 2 Stellen Sie mit dem Schieberegler die Vergr erung und Verkleinerung ein Hinweis Sobald der Schieberegler aktiv ist k nnen Sie die Pfeiltasten links und rechts der Tastatur zur Feineinstell...

Page 19: ...Internal Preset Memory tab The buttons are used to Save and Load Internal Preset data or Print the current settings If desired add a description in the Program Description field Click to save an Inter...

Page 20: ...t Current value as 12 0A Input Command GETS CR Return value voltage current CR OK CR Get PS preset Voltage Current value voltage current Input command GETS CR Return value 150180 CR OK CR Meaning The...

Page 21: ...ber start from 0 to 2 Input command PROM111111022122033133 CR Return value OK CR Meaning Preset Memory 0 as 11 1V and 11 1A Preset Memory 1 as 2 2V and 12 2A Preset Memory 2 as 3 3V and 13 3A Input Co...

Page 22: ...40CVAC 50 60Hz Sicherung 8 A 250 V 5 x 20 mm 120 V 4 A 250 V 5 x 20 mm 220 V Volllaststrom 6 2 A 120 V 3 25 A 220 V Installation category CAT 2 Other Efficiency 89 Switching Frequency 65 to 85 kHz app...

Page 23: ...ad and output setting Allow the unit to cool for at least 30 minutes Check to see if any ventilation holes are blocked also check that there is sufficient clearance around the power supply Listen care...

Page 24: ...or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed...

Page 25: ...entel La responsabilit totale de FLIR est limit e la r paration ou au remplacement du produit La garantie d finie ci dessus est inclusive et aucune autre garantie crite ou orale n est exprim e ou impl...

Page 26: ...cidentales o consecuentes La responsabilidad total de FLIR est limitada a la reparaci n o reemplazo del producto La garant a precedente es inclusiva y no hay otra garant a ya sea escrita u oral expres...

Reviews: