Operation

 

Hinweis:

  

Die

 

maximale

 

Ausgangsspannung

 

des

 

DC60

 

beträgt

 

60

 

VDC.

 

Der

 

Summennennstrom

 

beträgt

 

(Aux+Haupt)

 

10A

 

 

 

 

Powering

 

the

 

Supply

 

Check

 

the

 

rating

 

label

 

of

 

the

 

power

 

supply

 

and

 

ensure

 

that

 

it

 

complies

 

with

 

the

 

AC

 

mains

 

voltage

 

that

 

is

 

to

 

be

 

used.

 

Connect

 

the

 

power

 

supply

 

to

 

the

 

AC

 

Mains

 

using

 

the

 

provided

 

power

 

cord.

 

Ensure

 

that

 

the

 

Mode

 

Switch

 

(8)

 

is

 

set

 

to

 

the

 

Normal

 

Mode

 

position.

 

The

 

Model

 

DCP60

 

requires

 

a

 

110VAC

 

power

 

source

 

and

 

the

 

DCP

220

 

requires

 

a

 

220V

 

power

 

source.

 

 

Switching

 

the

 

Power

 

Supply

 

ON

 

and

 

Self

Test

 

Information

 

The

 

power

 

supply

 

will

 

perform

 

a

 

series

 

of

 

self

tests

 

when

 

it

 

is

 

switched

 

on.

 

The

 

LED

 

and

 

other

 

indicators

 

on

 

the

 

front

 

panel

 

will

 

illuminate

 

in

 

sequence.

 

When

 

the

 

cooling

 

fan

 

is

 

being

 

checked,

 

a

 

high

 

speed

 

wind

 

sound

 

can

 

be

 

heard.

 

After

 

the

 

self

tests,

 

the

 

CV,

 

V

 

and

 

A

 

LED

 

indicators

 

are

 

lit

 

displaying

 

voltage

 

and

 

0.0

 

current.

 

To

 

find

 

the

 

CC

 

current

 

level,

 

turn

 

the

 

current

 

control

 

knob

 

one

 

click

 

in

 

either

 

direction.

 

The

 

current

 

display

 

returns

 

to

 

0.0

 

after

 

a

 

few

 

seconds.

 

The

 

table

 

below

 

details

 

the

 

self

test

 

sequence:

 

 

Self

test

 

displays

 

Test

 

 

Software

 

version

 

 

Segment

 

check

 

 

C.V.

 

Indicator

 

check

 

 

C.C.

 

Indicator

 

check

 

 

Rear

 

control

 

indicator

 

check

 

 

Return

 

to

 

C.V.

 

 

Start

 

to

 

check

 

 

Over

 

voltage

 

protection

 

check

 

 

Over

 

load

 

protection

 

check

 

 

Over

 

temperature

 

protection

 

check

 

 

Fan

 

check

 

 

Output

 

off

 

(remote

 

control

 

mode)

 

Summary of Contents for DCP60

Page 1: ...USER GUIDE Model DCP60 and Model DCP60 220 Switching Mode DC Power Supplies 60V 10A Adjustable...

Page 2: ...nd can be performed without output spiking The Remote Control feature permits output ON OFF and Voltage Current adjustments The USB port offers PC connectivity for programming and running ramp cycles...

Page 3: ...ains 4 Refer all servicing to qualified service personnel only 5 Before replacing the AC fuse determine the cause and clear up the cause first 6 Replace the AC fuse with the same type and rating as th...

Page 4: ...Current Control Knob controls both the main and auxiliary output current limit 5 Power ON OFF Switch 6 Aux output terminal max 5A The total rated current Aux Main is 10A REAR PANEL 7 Haupt Ausgangskle...

Page 5: ...2 P3 available using the Recall Selection Switch 9 3 The preset values are factory set as shown in the table below 4 The user can change these output settings please refer to the next paragraph Recall...

Page 6: ...tory Default settings 1 Switch OFF the power supply 2 Push and hold both front panel voltage and current control knobs at the same time 3 Switch ON the power supply again 4 Release the front panel vol...

Page 7: ...ll perform a series of self tests when it is switched on The LED and other indicators on the front panel will illuminate in sequence When the cooling fan is being checked a high speed wind sound can b...

Page 8: ...uipment and Black is connected to the negative polarity input of the equipment 2 Switch ON the power supply first the panel meter green CV Indicator should illuminate 3 Next switch ON the equipment un...

Page 9: ...ote Socket Pin Assignment for external variable voltage source PIN FUNCTIONS REMARKS 1 Internal DC 5V Lower than 50mA 2 Voltage adjust 0 to 5V Externes VDC Signal 3 Current adjust 0 to 5V Externes VDC...

Page 10: ...istor 2 Voltage adjust Variable leg of resistor 3 Current adjust Variable leg of resistor 4 Ground Other end of resistor 5 Output OFF EIN Short to ground zum Ausschalten 6 N A 7 N A 8 N A Check the ou...

Page 11: ...5 to Pin 4 ground switches the output OFF When the output is OFF the C V C C LEDs will flash The present output voltage and current setting will be shown on the panel meter The user can adjust the out...

Page 12: ...execution of the installer file 8 When the Silicon Labs prompt appears select Install to load the necessary drivers onto your PC An older version of the drivers may already reside on your PC therefor...

Page 13: ...ormation 3 Voltage and Current setting panel Use this panel to set the output values and to switch the output On Off 4 Data handling panel Use this panel to save load and print data 5 External Timed P...

Page 14: ...ing 2 Current Output setting 3 Output ON OFF setting 4 SET confirm output values Directly type the value in the Voltage and Current fields or use the slider to set the Voltage and Current values and t...

Page 15: ...er t angeschlossen werden soll Stellen Sie mit dem Schieberegler die Datenlogger Abtastdauer Rate ein Stellen Sie den oberen Grenzwert der Ausgangsspannung UVL ein um Niederspannungsanwendungen zu sch...

Page 16: ...gswert erreicht ist Sobald der Schieberegler aktiv ist k nnen Sie die Pfeiltasten links und rechts der Tastatur zur Feineinstellung nutzen Stellen Sie die Dauer f r diesen Schritt ein wie in der Abbil...

Page 17: ...cher Die Fernsteuerung Vorbelegungsfunktion der PC Schnittstelle vereinfacht den langwierigen Eingabevorgang von Gruppen von Eintr gen Da alle Daten auf dem PC Monitor gleichzeitig dargestellt werden...

Page 18: ...er rechts 2 Stellen Sie mit dem Schieberegler die Vergr erung und Verkleinerung ein Hinweis Sobald der Schieberegler aktiv ist k nnen Sie die Pfeiltasten links und rechts der Tastatur zur Feineinstell...

Page 19: ...Internal Preset Memory tab The buttons are used to Save and Load Internal Preset data or Print the current settings If desired add a description in the Program Description field Click to save an Inter...

Page 20: ...t Current value as 12 0A Input Command GETS CR Return value voltage current CR OK CR Get PS preset Voltage Current value voltage current Input command GETS CR Return value 150180 CR OK CR Meaning The...

Page 21: ...ber start from 0 to 2 Input command PROM111111022122033133 CR Return value OK CR Meaning Preset Memory 0 as 11 1V and 11 1A Preset Memory 1 as 2 2V and 12 2A Preset Memory 2 as 3 3V and 13 3A Input Co...

Page 22: ...40CVAC 50 60Hz Sicherung 8 A 250 V 5 x 20 mm 120 V 4 A 250 V 5 x 20 mm 220 V Volllaststrom 6 2 A 120 V 3 25 A 220 V Installation category CAT 2 Other Efficiency 89 Switching Frequency 65 to 85 kHz app...

Page 23: ...ad and output setting Allow the unit to cool for at least 30 minutes Check to see if any ventilation holes are blocked also check that there is sufficient clearance around the power supply Listen care...

Page 24: ...or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed...

Page 25: ...entel La responsabilit totale de FLIR est limit e la r paration ou au remplacement du produit La garantie d finie ci dessus est inclusive et aucune autre garantie crite ou orale n est exprim e ou impl...

Page 26: ...cidentales o consecuentes La responsabilidad total de FLIR est limitada a la reparaci n o reemplazo del producto La garant a precedente es inclusiva y no hay otra garant a ya sea escrita u oral expres...

Reviews: