Introduction

 

Congratulations

 

on

 

your

 

purchase

 

of

 

the

 

CL500

 

chlorine

 

tester.

 

The

 

CL500

 

is

 

a

 

revolutionary

 

first

 

of

 

its

 

kind

 

measurement

 

device

 

that

 

measures

 

free

 

and

 

total

 

Chlorine

 

from

 

0.00

 

to

 

3.50

 

ppm.

 

The

 

electrode

 

method

 

employed

 

is

 

approved

 

by

 

the

 

U.S.

 

Environmental

 

Protection

 

Agency

 

(EPA)

 

as

 

an

 

acceptable

 

method

 

for

 

wastewater

 

compliance

 

monitoring

 

of

 

total

 

chlorine.

 

For

 

this

 

type

 

of

 

electrode

 

method,

 

a

 

reagent

 

tablet

 

must

 

be

 

added

 

to

 

the

 

measurement

 

solution

 

before

 

testing.

 

The

 

advantages

 

of

 

the

 

CL500

 

for

 

the

 

user

 

include:

 

easy

 

to

 

use

 

and

 

maintain,

 

high

 

accuracy,

 

self

calibration,

 

and

 

fast

 

response.

 

This

 

meter

 

is

 

shipped

 

fully

 

tested

 

and

 

calibrated

 

and,

 

with

 

proper

 

use,

 

will

 

provide

 

years

 

of

 

reliable

 

service.

 

Please

 

visit

 

our

 

website

 

(www.extech.com)

 

to

 

check

 

for

 

the

 

latest

 

version

 

of

 

this

 

User

 

Guide,

 

Product

 

Updates,

 

and

 

Customer

 

Support.

 

Applications

 

The

 

CL500

 

can

 

be

 

used

 

wherever

 

a

 

measurement

 

of

 

the

 

total

 

chlorine

 

in

 

water

 

as

 

needed.

 

This

 

is

 

also

 

referred

 

to

 

as

 

total

 

residual

 

chlorine.

 

It

 

measures

 

the

 

total

 

of

 

all

 

chlorine

 

present

 

in

 

all

 

forms,

 

including

 

dissolved

 

free

 

chlorine,

 

chloramines,

 

hypochlorous

 

acid,

 

and

 

hypochlorite

 

ion.

 

Typical

 

applications

 

include

 

Total

 

Chlorine

 

measurements

 

of

 

discharge

 

water

 

from

 

water

 

treatment

 

plants,

 

public

 

drinking

 

water

 

supplies

 

and

 

cooling

 

towers,

 

and

 

free

 

chlorine

 

measurements

 

of

 

the

 

disinfectant

 

properties

 

in

 

swimming

 

pools

 

and

 

cooling

 

water

 

applications.

  

Meter

 

Description

 

CL500

 

Front

 

Panel

 

Description

 

1.

 

Test

 

Bottle

 

Chamber

 

2.

 

Test

 

Bottle

 

Chamber

 

latch

 

3.

 

LCD

 

display

 

4.

 

POWER

 

button

 

5.

 

HOLD

 

button

 

6.

 

REC

MAX

MIN

 

button

 

7.

 

ZERO

 

button

 

8.

 

TEST

CAL

 

button

 

9.

 

Test

 

bottle

 

 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for CL500

Page 1: ...USER GUIDE Free and Total Chlorine Tester Patent Pending Model CL500 www com information itm com 1 800 561 8187 ...

Page 2: ...ease visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Applications The CL500 can be used wherever a measurement of the total chlorine in water as needed This is also referred to as total residual chlorine It measures the total of all chlorine present in all forms including dissolved free chlorine chloramines hypochlorous acid ...

Page 3: ...chamber 6 Close the cover and lock it in place 7 Press the POWER button to turn the meter ON The display will show Free or Total for 1 second and then CAL0 The meter is now ready for the zero test 8 Press the Zero button the display will flash tEST and then 0 00 ppm The Zero Test is now complete Do not power down the meter Measurement of Test Solution 1 Open the test chamber and remove the test bo...

Page 4: ...ode momentarily press the Rec button The display will show REC MAX Momentarily press the HOLD button the display will now show REC The Max value has been erased 6 To erase the Min value and continue recording while in the record mode momentarily press the Rec button The display will show REC MAX Press the REC button once again and now the display will show REC MIN Momentarily press the HOLD button...

Page 5: ...ease the CAL button 4 Clean the sides of the Zero Chlorine solution bottle and insert it into the testing chamber 5 Line up the white mark on the bottle with the white mark in the chamber and close the cover and latch it 6 Press CAL once more and the display will flash tEST and show the following 7 The meter is now ready for zero chlorine calibration 8 Press CAL button once The LCD will flash CAL ...

Page 6: ...rk on the bottle with the white mark in the chamber close and latch the cover 3 Press CAL once more the display will flash CAL and then show the following 4 When calibration is complete the LCD will return to the normal operating mode and measure the test solution The display should show 1 00 ppm 5 The meter is now ready to measure test solutions CAL 1 00 ppm www com information itm com 1 800 561 ...

Page 7: ...rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and ...

Page 8: ...m Sample Time Approximately 1 second Power Six 1 5 V batteries Power Consumption Stand By Mode approx 4mADC Testing Mode approx 12mADC Dimensions 155 x 76 x 62mm 6 1 x 3 0 x 2 4 320g 0 70lbs Auto Power OFF Automatically switches OFF 10 minutes after the last key press Method The measuring method is an adaptation of the USEPA method 330 5 and standard method 4500 Cl G Copyright 2014 2015 FLIR Syste...

Reviews: