background image

USER

 

GUIDE

 

 

 

Free

 

and

 

Total

 

Chlorine

 

Tester

 

Patent

 

Pending

 

 
 

Model

 

CL500

 

 
 
 
 
 
 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for CL500

Page 1: ...USER GUIDE Free and Total Chlorine Tester Patent Pending Model CL500 www com information itm com 1 800 561 8187 ...

Page 2: ...ease visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Applications The CL500 can be used wherever a measurement of the total chlorine in water as needed This is also referred to as total residual chlorine It measures the total of all chlorine present in all forms including dissolved free chlorine chloramines hypochlorous acid ...

Page 3: ...chamber 6 Close the cover and lock it in place 7 Press the POWER button to turn the meter ON The display will show Free or Total for 1 second and then CAL0 The meter is now ready for the zero test 8 Press the Zero button the display will flash tEST and then 0 00 ppm The Zero Test is now complete Do not power down the meter Measurement of Test Solution 1 Open the test chamber and remove the test bo...

Page 4: ...ode momentarily press the Rec button The display will show REC MAX Momentarily press the HOLD button the display will now show REC The Max value has been erased 6 To erase the Min value and continue recording while in the record mode momentarily press the Rec button The display will show REC MAX Press the REC button once again and now the display will show REC MIN Momentarily press the HOLD button...

Page 5: ...ease the CAL button 4 Clean the sides of the Zero Chlorine solution bottle and insert it into the testing chamber 5 Line up the white mark on the bottle with the white mark in the chamber and close the cover and latch it 6 Press CAL once more and the display will flash tEST and show the following 7 The meter is now ready for zero chlorine calibration 8 Press CAL button once The LCD will flash CAL ...

Page 6: ...rk on the bottle with the white mark in the chamber close and latch the cover 3 Press CAL once more the display will flash CAL and then show the following 4 When calibration is complete the LCD will return to the normal operating mode and measure the test solution The display should show 1 00 ppm 5 The meter is now ready to measure test solutions CAL 1 00 ppm www com information itm com 1 800 561 ...

Page 7: ...rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and ...

Page 8: ...m Sample Time Approximately 1 second Power Six 1 5 V batteries Power Consumption Stand By Mode approx 4mADC Testing Mode approx 12mADC Dimensions 155 x 76 x 62mm 6 1 x 3 0 x 2 4 320g 0 70lbs Auto Power OFF Automatically switches OFF 10 minutes after the last key press Method The measuring method is an adaptation of the USEPA method 330 5 and standard method 4500 Cl G Copyright 2014 2015 FLIR Syste...