background image

CG304-en-EU v1.1   7/14 

10

n

x

x

/

Statistical

 

Analysis

 

Considerations

 

The

 

meter

 

calculates

 

statistics

 

from

 

a

 

maximum

 

of

 

80

 

readings

 

(For

 

Group

 

1

 

through

 

Group

 

4,

 

a

 

maximum

 

of

 

400

 

readings

 

can

 

be

 

stored).

 

Note

 

that

 

readings

 

cannot

 

be

 

stored

 

when

 

in

 

DIRECT

 

mode.

 

However,

 

statistics

 

on

 

these

 

readings

 

can

 

still

 

be

 

calculated.

 

When

 

the

 

meter

 

is

 

powered

 

off

 

or

 

if

 

the

 

working

 

mode

 

is

 

changed

 

(in

 

the

 

programming

 

menu),

 

the

 

DIRECT

 

mode

 

statistics

 

will

 

be

 

lost.

 

The

 

following

 

statistical

 

values

 

can

 

be

 

calculated:

 

 

NO.:

 

Number

 

of

 

readings

 

 

AVG:

 

Average

 

value

 

 

Sdev.

 

:

 

Standard

 

deviation

 

(square

 

root

 

of

 

a

 

data

 

set’s

 

variance)

 

 

MAX:

 

Maximum

 

reading

 

 

MIN:

 

Minimum

 

reading

 

 

Statistical

 

Terms

 

Average

 

value

 

(

x

)

 

is

 

the

 

sum

 

of

 

readings

 

divided

 

by

 

the

 

number

 

of

 

readings.

 

 

 
 

Standard

 

Deviation

 

(Sdev)

 

The

 

sample

 

standard

 

deviation

 

is

 

a

 

statistic

 

that

 

measures

 

how

 

the

 

sample

 

value

 

is

 

distributed

 

around

 

the

 

sample

 

mean.

 

The

 

standard

 

deviation

 

of

 

a

 

set

 

of

 

numbers

 

is

 

the

 

root

 

mean

 

square

 

of

 

the

 

variance

 

S

2

 

 

The

 

variance

 

of

 

a

 

list

 

is

 

the

 

square

 

of

 

the

 

standard

 

deviation

 

of

 

the

 

list,

 

that

 

is,

 

the

 

average

 

of

 

the

 

squares

 

of

 

the

 

deviations

 

of

 

the

 

numbers

 

in

 

the

 

list

 

from

 

their

 

mean

 

divided

 

by

 

the(number

 

of

 

readings

 ‐

1

 

)

 

 

Variance:

  

S

2

=

)

1

/(

)

(

2

n

x

x

  

Standard

 

deviation:

 

S=

2

S

 

 

NOTE:

 

Use

 

the

 

DELETE

 

parameter

 

from

 

the

 

programming

 

menu

 

immediately

 

after

 

an

 

outlier

 

or

 

erratic

 

reading

 

has

 

been

 

taken.

 

Refer

 

to

 

the

 

Delete

 

function

 

in

 

Programming

 

Menu.

 

 

Storage

 

Capacity

 

Overflow

 

 

In

 

GROUP

 

mode,

 

if

 

the

 

storage

 

capacity

 

is

 

exceeded,

 

statistics

 

will

 

not

 

be

 

updated,

 

although

 

measurements

 

can

 

still

 

be

 

made.

 

If

 

the

 

memory

 

is

 

full,

 

subsequent

 

readings

 

will

 

not

 

be

 

included

 

in

 

the

 

statistics.

 

The

 

meter’s

 

display

 

will

 

show

 

“FULL”

 

(in

 

the

 

SINGLE

 

measurement

 

mode).

 

In

 

DIRECT

 

mode,

 

when

 

the

 

memory

 

is

 

full,

 

the

 

newest

 

reading

 

will

 

replace

 

the

 

oldest

 

reading

 

and

 

the

 

statistics

 

will

 

be

 

updated.

 

 

Summary of Contents for CG304

Page 1: ...USER GUIDE Coating Thickness Tester With Bluetooth Model CG304 ...

Page 2: ... care of this meter will provide many years of reliable service Description Meter Description 1 LCD display 2 Power key 3 Probe 4 ARROW buttons Note Battery compartment on rear of meter Display Icon Description NFe Non ferrous metals Fe Ferrous metals AUTO Automatic substrate recognition F or N Calibration icons DIR DIRECT mode GRO1 4 GROUP Mode number µm Micrometers unit of measure mils mils mill...

Page 3: ...eference film 3 In the single mode the meter will emit an audible tone indicating that the measurement has been taken 4 In the continuous mode the display will continually measure and update the display 5 The LCD will show the reading 250µm at the center of the display area 6 A typical display will also show the following NO 1 reading number one on the lower left of the LCD AVG 250µm running avera...

Page 4: ...surement mode No Fe Non ferrous measurement mode Unit settings µm Micrometers mils Mils mm 2 54 100 mm Millimeters Backlight ON Enables backlight operation OFF Disables backlight operation LCD Statistics AVG Average of a series of readings MAX Highest of a series of readings MIN Lowest of a series of readings SDEV Standard deviation of a series Auto Power OFF Enable Allows auto power off to operat...

Page 5: ... the CONTINUOUS measurement mode the meter displays a running average of readings as they are taken Note that the audible measurement beep is not active in this mode In the SINGLE measurement mode measurements are taken one at a time Single mode measurement readings are accompanied by an audible tone b Working Modes Select DIRECT or GROUP 1 2 3 or 4 under WORKING MODES in the OPTIONS Menu using th...

Page 6: ...st the brightness of the backlight f LCD Statistics Select AVERAGE MINIMUM MAXIMUM or SDEV Standard Deviation under LCD STATISTICS in the OPTIONS Menu using the arrow buttons and the SELECT soft key This selection determines which statistic is shown as default on the LCD display g Auto Power OFF Select ENABLE or DISABLE under AUTO POWER OFF in the OPTIONS Menu using the arrow buttons When enabled ...

Page 7: ...scroll down to MEASUREMENT VIEW 3 Press LEFT to open the MEASUREMENT VIEW parameter 4 User the ARROW buttons to scroll through the stored readings CALIBRATION Menu The Calibration menu allows the user to enable disable the calibration utility The Calibration menu also allows the user to delete Zero calibration data for both ferrous Zero F and non ferrous Zero N modes 1 Press the LEFT button to acc...

Page 8: ...nsiderations The calibration sample must correspond to the product sample in the following ways Curvature radius Substrate material properties Substrate thickness Size of measurement area The point at which the calibration is made on the calibration sample must always be identical with the point of measurement on the product itself especially in the case of corners and edges of small parts To achi...

Page 9: ...menu d Press UP DOWN button to select zero point calibration e Press LEFT to enter or RIGHT to return to measurement mode f Press LEFT button to confirm calibration 2 Press and hold the DOWN button to enter zero point calibration of Fe in measuring mode 3 Press and hold UP button to enter zero point calibration of Non Fe measuring mode Delete Fe or Non Fe zero point 1 Press LEFT button to enter me...

Page 10: ...t measures how the sample value is distributed around the sample mean The standard deviation of a set of numbers is the root mean square of the variance S 2 The variance of a list is the square of the standard deviation of the list that is the average of the squares of the deviations of the numbers in the list from their mean divided by the number of readings 1 Variance S 2 1 2 n x x Standard devi...

Page 11: ...al device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause ...

Page 12: ...erating in conjunction with any other antenna or transmitter 2 This equipment complies with RSS 102 RF radiation exposure limits set forth for an uncontrolled environment 3 To maintain compliance with RSS 102 RF exposure compliance requirements avoid direct contact to the transmitting antenna during transmission Error Messages The following error messages will appear on the meter s LCD if a proble...

Page 13: ...y door 2 Open the battery compartment 3 Replace install the two 1 5V AAA batteries 4 Secure the battery compartment Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of th...

Page 14: ...Min area 275 6mils 7mm 196 9mils 5mm Basic critical thickness 19 69mils 0 5mm 11 81mils 0 3mm Industrial standards Conforms to GB T 4956 1985 GB T 4957 1985 JB T 8393 1996 JJG 889 95 and JJG 818 93 Operating Temperature 0 C 40 C 32 F 104 F Operating Relative Humidity R H 20 90 Relative Humidity Dimensions 120 x 62 x 32 mm 4 7 x 2 4 x 1 25 Weight 175g 6 17 oz 1 Accuracy note Accuracy statement appl...

Reviews: