3                                      CO210-en-EU_V1.2   8/14 

Operation 

POWER ON 

Plug in the adaptor and the meter turns on automatically with a short beep. If the voltage is 
too high or low, “

bAt

“ will display on the LCD and an LED will flash.  

The LCD will display current CO

2

, temp., humidity, date and time. The air quality level is 

displayed as well  

 
 

 

 
 
 

TAKING MEASUREMENT 

The meter starts measurements when powered on and updates readings every second. If the 
operating environment changes (ex. from high to low temp.), it takes 2 minutes for the CO

sensor 

to respond and 10 minutes for RH change.  

NOTE: Do not hold the meter close to your mouth or any other source of CO

2

 

MAX/MIN 

In the normal mode, press the MIN/MAX button to see the minimum and maximum of CO

2

Temperature and Humidity. Each press of MIN/MAX button will sequence through the MIN, MAX 
display and then returns to normal mode. 
Press and hold the RESET button for more than 1 second to clear the minimum and maximum 
value from memory. 

DATA LOGGING 

The meter can record readings of CO

2, 

, temperature and humidity for long time environment 

monitoring. The memory capacity is 15999 points (5,333 RH, Temperature and CO

2

 records) . 

The sample rate is adjustable from 1 second to 4 hours 59 minutes and 59 seconds. 

After the sampling rate is selected, press the 

LOG

 button for 2 seconds in the normal 

mode to start logging. The green LED light blinks to indicate the logging status and the LCD 
main display will alternate between real time CO

2

 value and “rEC”. The lower displays are 

the real time temperature, humidity and clock. 

To terminate data logging, press the 

ESC

 button” for 2 seconds. The LED will stops blinking 

and the LCD main display will alternate between real time CO

2

 value and “End”. Hold down 

the ESC button for 2 seconds again and it the meter returns to normal measurement mode. 

Minimum and Maximum recall continues working during logging. 

The memory is cleared whenever a new logging session is activated. 

 

Summary of Contents for 793950502105

Page 1: ...User s Guide CO2 Monitor and Datalogger Model CO210...

Page 2: ...Date and Time 3 Air Temperature 4 Relative Humidity Symbols ppm CO2 value GOOD CO2 air quality level NORMAL CO2 l air quality level POOR CO2 air quality level Air Temp Air Temperature Humidity Relati...

Page 3: ...he RESET button for more than 1 second to clear the minimum and maximum value from memory DATA LOGGING The meter can record readings of CO2 temperature and humidity for long time environment monitorin...

Page 4: ...ode for more than 1 second to enter the setup mode P1 1 CO2 ALARM GOOD LEVEL When entering the setup mode P1 0 and CO2 are displayed on the LCD Press the SET button again to go into P1 1 for setting t...

Page 5: ...ange the units Press the SET button to confirm the setting or press the ESC button to exit without saving and return to P2 0 P3 0 REAL TIME CLOCK Press the LOG button in P1 0 twice to access P3 0 for...

Page 6: ...settings Parameter Default P1 1 700ppm P1 2 1000ppm P1 3 1000ppm P2 1 C P4 1 No P5 0 SAMPLING RATE Press the LOG button in P1 0 three times to access P5 0 to set the logging sample rate The available...

Page 7: ...ation is suggested to be done outdoors on a sunny day with good ventilation and fresh air where the CO2 level is approximately 400 ppm Do not calibrate on a rainy day because high humidity will affect...

Page 8: ...Humidity 0 1 to 99 9 0 1 3 10 to 90 5 10 or 90 Display LCD Sensor Type CO2 NDIR non dispersive infrared technology Humidity Capacitance sensor Temperature air Thermistor Response CO2 2min for 90 step...

Page 9: ...if it still appear re calibrate the meter If above two methods faile return for repair E17 ABC mode of CO2 senor has failed and might cause wrong CO2 readings Send back for repair Temp Display E02 Air...

Page 10: ...lead to serious oxygen deprivation resulting in permanent brain damage coma and even death Regulatory exposure limits ASHRAE Standard 62 1989 1000ppm CO2 concentration in occupied building should not...

Reviews: