User's Guide 

 

 

 
 

Heavy Duty 
Differential Pressure Manometer 
 
Model 407910

 

 

Distributed by MicroDAQ.com, Ltd.                   www.MicroDAQ.com                   (603) 746-5524

Summary of Contents for 407910

Page 1: ...User s Guide Heavy Duty Differential Pressure Manometer Model 407910 Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 ...

Page 2: ...ayed reading Sensor Built in piezoelectric sensors Zero Adjust Front panel push button Sample rate 0 8 sec approx Compatibility Air or non corrosive and non ionized gas Auto Power OFF Meter turns off after approx 10 minutes to conserve energy Data Output RS 232 PC serial interface Ambient conditions 32 to 122 o F 0 to 50 o C 80 RH Battery power 9V alkaline battery Power Consumption 8mA DC approx D...

Page 3: ... MAX recording mode as described later in this manual UNIT Press to select the unit of measure 3 0 16 4mm Quick disconnect fittings supplied 4 P1 Input 0 16 4mm accepts quick disconnect connector 5 RS 232 PC interface jack 3 5mm For use with data acquisition software hardware interface kit model 407001 6 P2 input 0 16 4mm accepts quick disconnect connector 7 Rubber protective holster removable 8 B...

Page 4: ...ol MBAR m at bottom of the LCD and Bar at the top Kg cm2 Kg cm 2 mm of Hg mm Hg m H2O m H2O Atmospheres ATP PSI PSI Inches of Hg in Hg Inches of H2O inch H2O Zero Adjust and Offset function Before use and without fittings attached to the meter press the ZERO button to calibrate the meter s circuitry The display should then indicate zero If it is desired to offset the meter s display press the ZERO...

Page 5: ...ing will appear on the display 3 Press the RECORD RECALL button again the MIN indicator and the minimum value will appear on the display 4 To return to normal operation press and hold the RECORD RECALL button until the display indicators REC MAX and MIN disappear RS 232 PC Interface The meter has a built in RS 232 serial port For streaming of data to a PC via the RS232 Output jack the optional 407...

Page 6: ...ctive jacket by stretching it over the bottom of the meter 2 Pry open the battery compartment located on the back of the meter using a small coin or screwdriver 3 Replace the 9V alkaline battery 4 Replace the battery compartment cover and the protective jacket Useful Conversions Useful conversion Factors From To Multiplier In of H2O In of Hg 0 07355 In of H2O Cm of Hg 2 54 mm of Hg In of H2O 0 039...

Page 7: ... total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration Repair and Customer Care Services FLIR Systems Inc offers repair and calibration services for the Extech Instruments products we sell NIST certification for most products is also provided Call the Customer Se...

Page 8: ... FLIR est limitée à la réparation ou au remplacement du produit La garantie définie ci dessus est inclusive et aucune autre garantie écrite ou orale n est exprimée ou implicite Calibrage réparation et services après vente FLIR Systems Inc offre des services de calibrage et de réparation pour les produits Extech Instruments que nous commercialisons Nous fournissons également une certification NIST ...

Page 9: ...ponsabilidad total de FLIR está limitada a la reparación o reemplazo del producto La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral expresa o implícita Servicios de calibración reparación y atención a clientes FLIR Systems Inc ofrece servicios de reparación y calibración para los productos que vendemos de Extech Instruments Además ofrecemos certificación NIST para la...