Model 382152 Ver. 1.6 April 2001
3
Specifications
Measurements
Earth ground resistance (in 3 ranges) and AC voltage to 200V
Display
3-1/2 digit (1999 count) LCD with LED test status indicator
Data hold
Freezes latest reading on the LCD display
Automatic Test
3 minute test timer with automatic power down
Measurement trigger
Push-button single reading or 3 minute automatic test lock
Test lead length
Red: 50' (15m), Yellow: 33' (10m), Green: 16' (5m)
Power supply
Six 1.5V 'AA' batteries (included)
Low battery indication
LCD displays 'B' icon
Over-range indication
'1' displayed as most significant digit
Safety
IEC-1010 (EN-61010) category III
Weight
27.7oz. (800g) with batteries
Dimensions
6.42 x 3.94 x 2" (163 x 100 x 50 mm)
Supplied accessories
Test leads (3), auxiliary earth bars (2), six 'AA' batteries,
and carrying case
Range Specifications
Measurement
Range
Resolution
Accuracy
Earth Ground Resistance
2mA test current (820Hz)
20, 200, 2000
Ω
0.01
Ω
, 0.1
Ω
, 1
Ω
± (2% rdg + 2 d)
Earth Voltage
Frequency: 40 to 500Hz
0 to 200VAC
0.1V
± (1% rdg +2d)
Meter Description
1. Earth ground test lead terminal
2. Test status LED
3. Data Hold switch
4. Automatic 3-min. test OFF button
5. LCD Display
6. C1, P1 Aux bar test lead terminals
7. Function select switch
8. Resistance range select switch
9. Push-button momentary test
10. Automatic 3-min. test ON button
1
2
3
4
5
6
7
8
9
10