2                                     381277       Ver. 1.6    03/00

 

Adapter plug connects to the DMM "V" volts input terminal and the Adapter's 

negative plug connects to the DMM "COM" (-) input terminal. Power the DMM and set 

its function switch to the mV DC range. (Use the VDC setting if mV setting is not 

available). If you are using an Auto Range DMM, disable the Auto Range function 

and use Manual Range mode. 

 
4.2

 

Power the Adapter and Select Temperature Units

 

Move the "OFF/C/F" Switch to either the degrees F or C position as desired. The 

Adapter is now powered (observe the red LED power light) and the units of 

measure are selected. To remove power to the meter, move this switch to the OFF 

position and observe that the red LED indicator extinguishes. If the red status LED 

does not light when the meter is switched on, replace battery. 

 
4.3 Measurement Considerations

 

The supplied Type K Thermocouple can measure temperatures up to 650

o

F. The 

Adapter can accept other thermocouples which can measure higher temperatures 

(up to 2000

o

F). Contact Extech or you local distributor for other thermocouple probe 

types. 

 

5. MAINTENANCE 

5.1 Battery Replacement 

Remove the three (3) Phillips head screws on the rear of the Adapter and open the 

housing. Replace the battery and secure the adapter housing.    

 

5.2 Cleaning 

Caution:

 Use only a dry cloth to clean the plastic case. 

 

6. CALIBRATION / REPAIR SERVICES 

Extech offers complete repair and calibration services for all of the products we sell. For 

periodic calibration, NIST certification or repair of any Extech product, call customer 

service for details on services available. Extech recommends that calibration be 

performed on an annual basis to insure calibration integrity. 

 

7. WARRANTY 

EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and 
workmanship for one year from date of shipment (a six month limited warranty applies on sensors 
and cables). If it should become necessary to return the instrument for service during or beyond the 
warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210  for 
authorization. A Return Authorization (RA) number must be issued before any product is returned to 
Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to 
prevent damage in transit. 
This warranty does not apply to defects resulting from action of the user such as misuse, improper 
wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. 
Extech specifically disclaims any implied warranties or merchantability or fitness for a specific 
purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's 
total liability is limited to repair or replacement of the product. 

Reviews: