38073A-en-GB_v1.0 9/16
8
Specifications
Specifications stated for ambient conditions 23
o
C ±2
o
C (73.4
o
F
±3.6
o
F); Relative Humidity < 60%
Function
Range
Accuracy
AC Voltage
10 / 50 / 250 / 300 VAC
± 5% of Full Scale
DC Voltage
2.5 / 10 / 50 / 250 / 300 VDC ± 4% of Full Scale
DC Current
10 / 250 mA
± 4% of Full Scale
Resistance
Rx10 / Rx1K
± 4% of Full Scale
Battery Test 1.5V / 9V
Decibels
-20dB to +22dB (AC Voltage range 10V)
Sensitivity
10kΩ per 1VDC / 4.5kΩ per 1VAC
General Specifications
Display
Analog with Zero Adjustment
Operating Temp./Humidity 18 - 25°C (64 - 77°F); <75% RH
Operating Altitude
2000m (7000 ft.) maximum.
Battery
One (1) 1.5V ‘AA’ Battery
Fuse
500 mA / 500V fast blow
Dimensions
116 x 68 x 34 mm (4.6 x 2.7 x 1.3”)
Weight
120g (4.2 oz.)
Safety Compliance EN61010-1: CATIII 300V; Pollution Degree 2
Ingress Protection Rating IP20
Standards
CE and ETL
Copyright © 2016 FLIR Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form
www.extech.com
Shop for Extech products at:
1.888.610.7664
ShopExtech
.com