© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved

 

 6. VCOM Admin Utility

 

Please check if the COM

-

Port has been added in the device manager! The following entry should 

now be visible in the device manager:

 

3. Changing the settings of the serial interface: 

If you change the settings of the serial interface 

to values other than the default values (e.g. Device Description, Password, ...), you must first log in 
to the Device Server (the default password for this is "

system

"). 

 

Click 

Remote Device Management 

Login

 

Summary of Contents for EX-6111

Page 1: ...Vers 1 0 20 01 21 Ethernet to 1x Seriell RS 232 EX 6111 Ethernet zu 1x Seriell RS 232 Manual Anleitung...

Page 2: ...gung 12 8 Technische Daten 12 9 Technische Zeichnung 13 Inhaltsverzeichnis Index Copyright 2021 by EXSYS Vertriebs GmbH All Rights Reserved 1 Description 13 2 Extent of Delivery 13 3 Layout Connection...

Page 3: ...OM der Ihre serielle Anwendung perfekt migriert ohne die Software zu modifizieren Dar ber hinaus k nnen serielle Ger te mit dem Remote Pair Master Slave Modus ber den Peer to Peer Modus miteinander ko...

Page 4: ...5V DC Anschluss f r beiliegendes Netzteil Power ACT LED PoE LED TXD LED RXD LED Reset Schalter 3 2 Anschl sse LED s RJ45 Anschluss RJ45 Anschluss Pin Signal Pin Signal Pin Signal 1 BI_DA 4 BI_DC 7 BI...

Page 5: ...den werden ca ben tigt Aus Das Ger t ist ausgeschaltet TXD LED oben Gr n Blinken Die serielle Schnittstelle sendet Daten Aus Die serielle Schnittstelle sendet keine Daten RXD LED unten Gr n Blinken Di...

Page 6: ...er teserver Werkseinstellung Der EX 6111 wird mit folgenden Werkseinstellungen ausgeliefert Login User Name admin Password system IP Address DHCP Automatisch zugewiesen Network Operation Mode VCOM Mod...

Page 7: ...itgelieferte VCOM Admin Utility vspsetup exe installieren Das Installationsprogramm befindet sich auf der im Lieferumfang enthaltenen Treiber CD in folgendem Ordner Wichtig Bitte f hren Sie das Instal...

Page 8: ...rved 6 VCOM Admin Utility 2 Zuordnung der COM Ports Um den virtuellen COM Anschluss zu erstellen und dem seriellen Ger t zuzuordnen klicken Sie auf COM Mapping Add COM OK Um die COM Port Nummer zu nde...

Page 9: ...te nun folgen der Eintrag im Ger temanager sichtbar sein 3 ndern der Einstellungen der seriellen Schnittstelle Wenn Sie die Einstellungen der seriel len Schnittstelle auf andere Werte als die Standard...

Page 10: ...Utility Nachdem Sie eingeloggt sind klicken Sie auf Remote Device Management und dann Doppelklick auf den ausgew hlten Device Server in der Liste Doppelklick Klicken Sie auf Remote Device Management D...

Page 11: ...Modbus UDP TCP Client als den Standard VCOM Modus ndern m ssen Sie stattdessen den Webbrowser verwenden Um das Web Konfigurationsmen zu ffnen klicken Sie auf Remote Device Management w hlen Sie Device...

Page 12: ...che Daten Datentransfer Rate 50 bis 921 6 Kbps Baud Rate Anschl sse 1x 9 Pin D SUB serieller Stecker 1x RJ45 Ethernet Anschluss 1x 5V DC Buchse Hardwaresystem Ethernet 10 100 Mbit s VCOM Admin Utility...

Page 13: ...irtual COM port redirection driver VCOM that perfectly migrates your serial application without modifying the software In addition serial devices with remote pair master slave mode can communicate wit...

Page 14: ...D PoE LED TXD LED RXD LED Reset Button Copyright 2021 by EXSYS Vertriebs GmbH All Rights Reserved 3 2 Connections LED s RJ45 Port RJ45 Port Pin Signal Pin Signal Pin Signal 1 BI_DA 4 BI_DC 7 BI_DD 2 B...

Page 15: ...om power up Off The unit is not booted yet TXD LED above Green Blinking The Serial Port is sending out data Off The Serial Port is not sending out any data RXD LED below Green Blinking The Serial Port...

Page 16: ...Configuration of the Device Server Factory Settings The EX 6111 is delivered with the following factory settings Login User Name admin Password system IP Address DHCP Assigned Automatically Network O...

Page 17: ...IP address you must install the VCOM Admin Utility vspsetup exe that comes with the device The installation program is located on the driver CD included in the scope of delivery in the following fold...

Page 18: ...GmbH All Rights Reserved 6 VCOM Admin Utility 2 Assignment of COM Ports To create the virtual COM Port and assign it to the serial device click COM Mapping Add COM OK To change the COM Port number cli...

Page 19: ...ager The following entry should now be visible in the device manager 3 Changing the settings of the serial interface If you change the settings of the serial interface to values other than the default...

Page 20: ...t 2021 by EXSYS Vertriebs GmbH All Rights Reserved After you are logged in click Remote Device Management and then double click the selected device server in the list Click Remote Device Management do...

Page 21: ...operation mode to other modes e g Modbus UDP TCP Client than the default VCOM mode you must use the web browser in stead To open the web configuration menu click Remote Device Management select Devic...

Page 22: ...cleaning 8 Technical Information 9 Technical Drawing Data Transfer Rate 50 to 921 6 Kbps Baud Rate Connectors 1x 9 Pin D SUB serial Connector 1x RJ45 Ethernet Port 1x 5V DC Connector Hardware System E...

Page 23: ......

Page 24: ......

Reviews: