Preparation for Operation - 1
Input Cable Connection:
Check the input voltage, phases and frequency before operating the machine. Usable input
voltage values are indicated in the manual's technical specifications section and the plate on the
machine. Be sure that the grounding of the cables which connects the machine to the input
electricity are appropriate. Be sure that enough current is provided for the machine's normal
operation. Recommended fuse type and size is 25 Amps (delayed).
1 - This machine is designed to operate with 220-230 V, 1 Ph, AC 50-60 Hz supply voltage.
2 - Never operate the machine or connect to the input without a proper, protected grounding
(confirmed by authorized electrician). Electrical leakage contains fatal danger for human
health.
3 - Shouldn't be connected to 3 phased input. If the supply will be made from 3 phased input, an
isolated receptacle connection should be made to the the machine supply plug (within 220 V)
and this procedure should be performed by a qualified electrician. Incorrect connections may
damage the machine and damages caused by this kind of connections will void the warranty.
Controls and Operating Specifications:
Rear Panel
5
6
Front Panel
2
3
1
4
7