ML501_ET | v18
Page
4
Expo Technologies UK
T: +44 (0) 20 8398 8011
Expo Technologies US
T: +1 (440) 247 5314
Expo Technologies China
T: +86 532 8906 9858
Section 2: Quick User Guide
Installation
The MiniPurge
®
S
ystem must be installed by a competent engineer, in accordance with relevant standards,
such as IEC / EN 60079-14 and any local codes or practice.
• Mount the purge system in accordance with the hook-up drawing.
• Ensure the system is installed according to the full instructions in the
“Installation of the System”
section of
this manual
.
• All pipings must be clean and free of dirt, condensation and debris prior to connection to the purge system
or pressurized enclosure.
• It is strongly recommended that a local isolation valve is installed on the air supply upstream of the purge
system.
Note: Most faults are due to restricted air supply, inadequate supply pipe work or drop in air supply
pressure during the purge process.
Operation of the System
Once the system is installed correctly, turn on the air supply. Refer to
Commissioning
section.
The purge system commences the purge cycle:
• The purge air will enter the enclosure.
• The pressurized enclosure will obtain a positive pressure.
• The Purge Outlet Valve will open within the Relief Valve Unit.
• The air will then exit the Relief Valve Unit housing via the spark arrestor.
Open the Purge Flow Restrictor Valve until the air flow reaches the required rate; the system will initiate the
timed purge cycle. Start a stopwatch when the purging indicator flashes yellow
On completion of an uninterrupted purge cycle of the required length, the system will indicate purge complete.
Indicator
Colour
Status
Alarm / Pressurized
Red
Low pressure alarm (enclosure pressure too low)
Purging
Black
Purge flow too low or not in purge mode
Indicator
Colour
Status
Alarm / Pressurized
Green
Pressurized (minimum enclosure pressure achieved)
Purging
Black
Purge flow too low
Indicator
Colour
Status
Alarm / Pressurized
Green
Pressurized
Purging
Sequential flashing
Yellow
Purge flow rate above minimum
Summary of Contents for MiniPurge D808/ET
Page 2: ......
Page 32: ...This Page Intentionally Left Blank...
Page 33: ...This Page Intentionally Left Blank...
Page 34: ...This Page Intentionally Left Blank...