EXPERT GRILL XG17-096-034-17 Owner'S Manual Download Page 3

Model No.

XG17-096-034-17

Page 3

LP gas cylinder must be arranged for vapor withdrawal.

   Dented or rusted LP gas cylinders may be hazardous and should be checked by your LP gas supplier 

prior to use.

   The LP gas cylinder should not be dropped or handled roughly. 

   LP gas cylinders must be stored outdoors out of the reach of children and must not be stored in a 

building, garage or any other enclosed area. Your cylinder must never be stored where temperatures 

can reach over 125°F. 

   Do NOT insert any tool or foreign object into the valve outlet or safety relief valve. You may damage 

the valve and cause a leak. Leaking propane may result in an explosion, fire, severe personal injury or 

death.

   Do NOT block holes in sides, bottom or back of grill.

   Never keep an LP gas cylinder in a hot car or trunk. Heat will cause the gas pressure to increase, 

which may open the relief valve and allow gas to escape.

   Never attempt to attach this grill to the self-contained LP gas system of a camper trailer, motor home 

or house.  

   Never use charcoal, lighter fluid, lava rocks, gasoline, kerosene or alcohol with this product.

   Your grill has been checked at all factory connections for leaks.  Recheck all connections as 

described in the “Operating Instructions” section of the manual, as shipping can loosen connections.

   Check for leaks even if your unit was assembled for you by someone else.

   Do NOT operate if a gas leak is present. Gas leaks may cause a fire or explosion.

   You must follow all instructions in the “Checking for Leaks” section before operating. To prevent a 

fire or explosion hazard when testing for a leak:

a.   Always perform a leak test before lighting the grill and each time the cylinder is connected for use.

b.   No smoking. Do NOT use or permit sources of ignition in the area while conducting a leak test. 

c.   Conduct the leak test outdoors in a well-ventilated area.  

d.   Do NOT use matches, lighters, or a flame to check for leaks. 

e.   The use of alcohol, prescription or non-prescription drugs may impair the consumer’s ability to 

properly assemble or safely operate the appliance.

f.   Strong odors, colds, sinus congestion, etc. may prevent the detection of propane. Use caution and 

common sense when testing for leaks. 

g.   Do NOT use grill until any and all leaks are corrected. If you are unable to stop a leak, disconnect 

the LP gas supply.  Call a gas appliance serviceman or your local LP gas supplier.

   Do NOT store or use gasoline or other flammable liquids or vapors 

within 25 feet (7.62 m) of this appliance.  

   Do NOT use in an explosive atmosphere. Keep grill area clear and free from combustible materials, 

gasoline and other flammable vapors and liquids.  

   Minimum clearance from sides and back of unit to combustible construction is 36 inches (91.4 cm). 

Do NOT use this appliance under any type of overhang or roof.

   It is essential to keep the grill’s regulator and valve assembly, burners and circulating air passages 

clean.  

  

Summary of Contents for XG17-096-034-17

Page 1: ...away from the appliance and immediately call your fire department Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death DANGER Never operate this appliance unattended Failure to follow the dangers warnings and cautions in this manual may result in serious bodily injury or death or in a fire or an explosion causing damage t...

Page 2: ... for and should never be used as a heater TOXIC fumes can accumulate and cause asphyxiation This grill is safety certified for use in the United States and or Canada only Do NOT modify for use in any other location Modification will result in a safety hazard and will void your warranty This grill is for use with liquid propane LP gas only The conversion to or attempted use of natural gas in this L...

Page 3: ...u by someone else Do NOT operate if a gas leak is present Gas leaks may cause a fire or explosion You must follow all instructions in the Checking for Leaks section before operating To prevent a fire or explosion hazard when testing for a leak a Always perform a leak test before lighting the grill and each time the cylinder is connected for use b No smoking Do NOT use or permit sources of ignition...

Page 4: ...readily accessible In the event of an oil grease fire do NOT attempt to extinguish with water Use type BC or ABC dry chemical fire extinguisher or smother with dirt sand or baking soda Do NOT use grill in high winds Never lean over the grill when lighting Do NOT leave a lit grill unattended Keep children and pets away from grill at all times Do NOT leave grill unattended while preheating or burnin...

Page 5: ...the product Never cover entire cooking area with aluminum foil Deaths serious injury or damage to property may occur if the above is not followed exactly The installation must conform with local codes or in the absence of local codes with theNational Fuel Gas Code ANSI Z223 1 NFPA 54 Storage and Handling ofLiquefied Petroleum Gases ANSI NFPA 58 orNatural Gas and Propane Installation Code CSAB149 1...

Page 6: ...avoid losing any small components or hardware assemble your product on a level sueface that does not have cracks or opening Clear an area large enough to layout all components and hardware and that is soft to not scratch or damage any surface finishes When applicable tighten all hardware connection by hand first Once the step is completed go back and fully tighten all hardware while being cautious...

Page 7: ...Model No XG17 096 034 17 Page 7 ...

Page 8: ...ption Image 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 2 1 1 2 1 1 1 1 2 1 1 1 1 1 Lid Lid Handle Cooking Grate Parts List Page 8 Lid Hinge Bowl Hinge Left Leg Right Leg Fire Bowl Side Handle Lock Heat Plate Burner Bottom Bowl Heat Shield Heat Plate Support Regulator Control Knob ...

Page 9: ...4 14 14 14 1 2 2 A B C D E F G Hardware Page 9 M5 12 Screw Washer Spring Washer Small M5 Wing Nut H I J K L M4 Wing Nut M4 12 Screw 2 2 M6 12 Screw Cotter Pin Hinge Pin M6 Wing Nut Large Washer Spring Washer Big 6 6 6 Tools Required for Assembly Not Included Phillips Head Screwdriver 1 1 ...

Page 10: ...Model No XG17 096 034 17 Step 1 Note Please find hardware J K L attached on lid handle Step 2 Page 10 ...

Page 11: ...Model No XG17 096 034 17 Step 3 Step 4 Note Please find hardware J K L attached on side handle Page 11 4 4 4 4 ...

Page 12: ...Model No XG17 096 034 17 Step 5 Step 6 Page 12 ...

Page 13: ...Model No XG17 096 034 17 Step 7 Step 8 Page 13 ...

Page 14: ...Model No XG17 096 034 17 Page 14 ...

Page 15: ...the OFF position Figure 2 2 Rotate LP gas tank counterclockwise until it is detached Figure 4 3 Store the LP gas tank in a proper location per instructions on the LP gas tank Checking for Leaks Burner Connections 1 Make sure the regulator control knob is securely fastened to the burner Note The brass nut should be 1 4 to 1 2 turn past tight The regulator will rotate 360º even when the brass nut is...

Page 16: ...lation air CAUTION Check and clean burner venturi tubes for insects and insect nests A clogged tube can lead to a fire CAUTION Attempting to light the burner with the lid closed may cause an explosion CAUTION Always open legs completely and secure in place before opening lid orlighting grill 1 Open lid 2 Check for obstructions of airflow to the burners Spiders insects and webs can clog the burner ...

Page 17: ...en cleaned a grease fire can occur that may damage the product WARNING When cooking fire extinguishing materials should be readily accessible In the event of an oil grease fire use type BC dry chemical fire extinguisher or smother with dirt sand or baking soda Do NOT attempt to extinguish with water Flare ups are a part of cooking meats on a grill and add to the unique flavor of grilling Excessive...

Page 18: ... For stubborn surfaces use a citrus based degreaser and a nylon scrubbing brush 3 Rinse clean with water 4 Allow to air dry Cleaning Main Burners 1 Turn regulator control knob to OFF Note A poof sound is normal as the last of the LP gas is burned 2 Disconnect LP gas tank per Disconnecting LP Gas Tank section 3 Remove regulator control knob 4 Remove cooking grid and heat plate 5 Disconnect wire fro...

Page 19: ...Gas Tank section 4 Clean all surfaces 5 Lightly coat the burner s and cooking grate with cooking oil to prevent excess rusting 6 If storing the grill indoors disconnect the LP tank per Disconnecting LP Gas Tank section 7 Place the protective cap cover on the LP tank and store the tank outdoors in a well ventilated area out of direct sunlight 8 If storing the grill indoors cover the grill and store...

Page 20: ...Model No XG17 096 034 17 Page 20 Bazhou Sanxin Steel Pipe Co Ltd Address Xin an Town Bazhou City Hebei Province China gas ...

Reviews: