EXPANSION ELECTRONIC ECOKITCHEN 1 Use And Instruction Manual Download Page 21

 

21 

 

 

For all the checks, use the wiring diagrams. 
 

Always cut off the voltage before operating on electrical circuits. 
 
Electrical maintenance is reserved for instructed and trained 

personnel only. 
 
Some interventions may require to operate on the panel UNDER 

TENSION, use the necessary precautions. 

 

 

2. 

ADJUSTMENTS POTENTIOMETER 

 
Inside at electric panel next to the potentiometer for adjusting the flow rate, there are 2 trimmers for setting 
the minimum flow rate and maximum flow rate. In production These trimmers are adjusted to obtain the 
maximum fan speed excursion, but due to the suction and unloading system these adjustments may have to 
be reset. 
 
For adjustment, proceed with the switchboard UNDER TENSION, danger risk of electrocution, proceed as 
illustrated below. 
 

     

ATTENTION ELECTRIC HAZARD    

 

 

 

 

– Open electric panel 

– Attention, having to operate with the panel 

UNDER TENSION, please observe all the 
appropriate precautions and to operate only and 
exclusively on the indicated components that work at 
LOW VOLTAGE (10 or 24 VDC) 

Summary of Contents for ECOKITCHEN 1

Page 1: ...USE AND INSTRUCTION MANUAL File 20190402 001 ELECTROSTATIC PURIFIER MODEL ECOKITCHEN TYPE 1 2 3 ...

Page 2: ...2 EXPANSION ELECTRONIC s r l via Delle Industrie 18 36050 Cartigliano VICENZA Web www expansion electronic com e mail info expansion electronic com ...

Page 3: ...NANCE 16 11 GENERAL CONTROL OF THE ELECTROSTATIC CELL AND PRE FILTER 18 12 CONTROLS ON THE ELECTROSTATIC FILTER 19 12 1 CLEANING THE IONISATION WIRES 19 12 2 REPLACING ELECTROSTATIC CELL IONISATION WIRES 19 13 ELECTRIC PANEL 20 2 ADJUSTMENTS POTENTIOMETER 21 3 TECHNICAL INFORMATION 23 16 1 TECHNICAL CHARACTERISTICS OF PURIFIER 23 16 2 CHARACTERISTICS OF ELECTRIC FAN 23 16 3 ECOKITCHEN 1 INSTALLED ...

Page 4: ...site by the user MACHINE COMPONENTS The machine is composed of A Structure containing the filters and the DEOX system B Structure containing the activated carbons and the fan C electric panel D screws and gasket kit E filtered air outlet A front and rear views B front and rear views C view of electric panel with brackets for wall mounting D screws and gasket kit for coupling For the commissioning ...

Page 5: ...ect the structure against any scratches and accidental blows do not place loads on top of it do not turn upside down do not expose to the elements All accessories are inserted inside the fan compartment During transportation the external structure and control panel of the machine must not be damaged so verify immediately at the time of delivery that there is no visible damage Sign the delivery rec...

Page 6: ...intenance of the filters as described in the attached filters manual POLLUTANTS THAT CAN BE FILTERED BY THE FILTERING SYSTEM The purifier can be used in the presence of pollutants having the following characteristics dry fumes low oil content fumes very fine powders up to 0 3 microns electrically chargeable fumes The machine was built for the most common pollutants such as food cooking fumes and v...

Page 7: ... placed on the floor create a raised supporting surface for the purifier if the machine is placed outdoors it is necessary to set up a canopy and walls that protect it from rain the electrical panel must always be placed in a dry place Any elements needed for installation supports canopies etc are not included in the supply and those using this machine must set them up at the site For installation...

Page 8: ...ed on the same plane to connect them together Bring the units close together with the outlet of the filtering section in front of the inlet of the ventilation section Apply the supplied adhesive gasket all along the entire perimeter of the filtering section ...

Page 9: ...with the relative screws using the relative self centring blocks Close with a 6mm Allen key The two joined sections will form a single body and will then be electrically connected together by the special electrical connector ...

Page 10: ...er supply using the special plug supplied with the electrical panel The connection must be set up by an electrician The earthing system shall be provided by the user The electrical supply network for the panel must meet the following conditions For machines with single phase power supply recognisable by a 3 pin BLUE plug Voltage 230V 10 Volt Frequency 50 60 Hz Minimum available power 1 5 kW For ma...

Page 11: ...his symbol WEEE on the package in the manual or on another part is subject to Directive 2003 96 EC and to Lgs D 151 2005 This product cannot be disposed of as urban waste but must be assigned to separate waste collection Any violation is penalised according to the current regulations Inquire about the methods established by local authorities for separate collection of electrical and electronic pro...

Page 12: ...ISTICS ECOKITCHEN systems are designed to provide an available head of 600Pa for intake and exhaust pipes at maximum air flow rate The table shows the flow and head values of the electric fan pressure is intended as available for pipes Model Maximum air flow rate m 3 h Useful pressure for pipes with clean filters Pa ECO1 2500 500 ECO2 4250 500 ECO3 6500 800 9 ECOKITCHEN COMPONENTS A B C D E F G H ...

Page 13: ...rticularly suitable for the abatement of pol lutants such as oil mists and vapours with and without par ticulate produced during cooking phases The main special feature of this filter is observed in the lower part of the collector blades where the specially designed shape allows high amounts of oily pollutant to drip with the reduced formation of electric discharges between the plates In addition ...

Page 14: ...itisation hygienisation and disinfection of air in plants and environments as it is able to de grade and eliminate any polluting or harmful elements such as viruses bacteria mites spores moulds insects and even harmful chemicals and unpleasant odours Thanks to its multipolar connection system it is possible to insert multiple ozonising cells according to the filtration and air flow requirements th...

Page 15: ...A longer contact time between air and activated carbons is obtained in this way subsequently increasing the odour ad sorption effect and reducing pressure drops In addition positioning the activated carbon battery after the filters and the FI FX modules extends their service life The panels can be opened to replace the activated carbon only thereby containing costs Diagram of air stream through th...

Page 16: ...e filter are worn replacement is recommended 10 1 WASHING THE PRE FILTER AND ELECTROSTATIC FILTER To perform correct maintenance as the first operation extract the pre filter incorporated in the electrostatic cell by lifting it for about one centimetre and extract it as shown in the figure For cleaning prepare 1 a plastic or stainless steel tank with decanting bottom 2 detergent we recommend the o...

Page 17: ...aults malfunctions or increase the frequency of maintenance 10 2 MAINTENANCE OF FI NEGATIVE IONISATION CELL The FI ionisation cell does not require frequent maintenance Every 6 months the emitting needles must be checked and kept clean and every 12 months they need to be replaced To clean the needles it is recommended to use a cotton swab dipped in multi purpose degreasing detergent If there are o...

Page 18: ...re show evident deposits of dirt it is possible to proceed to with washing as with the electrostatic filters DISPOSAL OF WASHING LIQUID The liquid must not be dispersed in the environment and must be disposed of as washing waste and must be taken to a suitable treatment plant 11 GENERAL CONTROL OF THE ELECTROSTATIC CELL AND PRE FILTER It is necessary to check the good state of the filters with eve...

Page 19: ...xide or deposits on the surface of the wire 12 2 REPLACING ELECTROSTATIC CELL IONISATION WIRES Ionisation wires are subject to wear due to the high voltage they are subjected to To avoid unexpected breakage it is a good rule to replace all ionisation wires once a year proceeding as follows a if an ionisation wire breaks remove all pieces of wire present in the cell and remove the springs that keep...

Page 20: ...of the open machine Close the filter access door with the special closures MACHINE DOES NOT START Machine door microswitch not pressed or broken Check that the microswitch press pin is intact and press the limit switch correctly Verify that the limit switch is working Verify that the cables are connected and intact Tripped thermal magnetic circuit breaker due to a short circuit Remove the short ci...

Page 21: ... 2 trimmers for setting the minimum flow rate and maximum flow rate In production These trimmers are adjusted to obtain the maximum fan speed excursion but due to the suction and unloading system these adjustments may have to be reset For adjustment proceed with the switchboard UNDER TENSION danger risk of electrocution proceed as illustrated below ATTENTION ELECTRIC HAZARD 1 Open electric panel 2...

Page 22: ...r to the minimum air flow position Start the machine and wait for the fan to start Turn the minimum trimmer until the desired speed is obtained 5 ADJUSTING THE MAXIMUM Bring the external potentiometer to the maximum air flow position Start the machine and wait for the fan to start Turn the maximum trimmer to the desired speed for maximum speeds It May be necessary to use a current probe to verify ...

Page 23: ...3G310 Electric power engine 3 4 kW Engine speed 350 to 3450 rpm variable ECOKITCHEN 2 TRIPHASE K3G315 Electric power engine 2 12 kW Engine speed 350 to 2680 rpm variable ECOKITCHEN 3 K3G400 Electric power engine 3 4 kW Engine speed 350 to 3450 rpm variable 16 3 ECOKITCHEN 1 INSTALLED FILTERS DESCRIPTION MODEL QUANTITY Filter reset CODE Sponge metal pre filter PFMST 1 washing PFMST592X592X95 Metal ...

Page 24: ...ALLED FILTERS DESCRIPTION MODEL QUANTITY Filter reset CODE Sponge metal pre filter PFMST 3 washing PFMST592X592X95 Metal mesh pre filter FE600 3 washing B03961 Electrostatic cell FEL600 3 washing XFE600L Ionisation cell FI600 3 washing XFI600 Ozonisation cell FX600 3 washing XFX600 Droplet separator turbulator CF FLX 6 washing B02736 Active carbon filter FCA600 18 replacement BB04093 4 SPARE PARTS...