CHAPTER 6: X-800C SPECIFICATIONS
24
THD, IM TIM
<.02%
Load Capacity
8
minimum impedance each channel
Cooling
Forced air cooling, two internal fans (one ultrahigh-speed reserve fan)
AC POWER
Connectors
250 V NEMA L6-20 inlet or IEC 309 male inlet
Automatic Voltage
Selection
Automatic, two ranges, each with high-low voltage tap (uninterrupted)
Safety Agency Rated
Operating Voltage
95–125 V AC; 208–235 V AC; 50/60 Hz
Turn-on/Turn-off
Points
85–134 V AC; 165–264 V AC; 50/60 Hz
Current Draw
Idle Current
0.64 A rms (115 V AC); 0.32 A rms (230 V AC); 0.85 A rms (100 V AC)
Maximum Long-Term
Continuous Current
8 A rms (115 V AC); 4 A rms (230 V AC); 10 A rms (100 V AC)
Burst Current
15 A rms (115 V AC); 8 A rms (230 V AC); 18 A rms (100 V AC)
Ultimate Short-Term
Peak Current
22 A peak (115 V AC); 11 A peak (230 V AC); 25 A peak (100 V AC)
Inrush Current
<7 A peak (115 V AC); <7 A peak (230 V AC); 10 A peak (100 V AC)
PHYSICAL
Enclosure
Premium birch plywood
Finish
Low-gloss, black-textured finish
Dimensions
31" w x 40" h x 21" d (787 mm x 1016 mm x 533 mm)
Weight
221 lbs (100.24 kg)
ENVIRONMENTAL
Operating Temperature
0° C to +45° C
Non Operating Tem-
perature
<–40° C or >+75° C
Humidity
to 95% at 35° C
Operating Altitude
to 4600 m (15,000 ft)
Non Operating Altitude
to 95% at 35° C
Shock
30 g 11 msec half-sine on each of 6 sides
Vibration
10 Hz – 55 Hz (0.010 m peak-to-peak excursion)
X-800C Specifications
Summary of Contents for X-800C
Page 6: ...CONTENTS vi ...
Page 12: ...CHAPTER 2 POWER REQUIREMENTS 12 ...
Page 20: ...CHAPTER 4 RMS REMOTE MONITORING SYSTEM 20 ...
Page 26: ...CHAPTER 6 X 800C SPECIFICATIONS 26 ...
Page 27: ......