23
CHAPTER 6: X-800C SPECIFICATIONS
X-800C Specifications
ACOUSTICAL
Operating Frequency
Range
20 Hz – 200 Hz
Note:
Recommended maximum operating frequency range. Response depends on loading condi-
tions and room acoustics.
Frequency Response
23 Hz – 160 Hz ±4 dB
Note:
Measured free field with 1/3 octave frequency resolution at 4 meters.
Phase Response
32 Hz to 175 Hz ±30°
Maximum Peak SPL
136 dB
Note:
Measured with music, referred to 1 meter.
Dynamic Range
>110 dB
Coverage
360° for a single unit; varies with number of units and configuration
TRANSDUCERS
Low Frequency
Two 18” cone drivers
Nominal impedance: 8
Voice coil size: 3”
Power-handling capability: 600 W (AES) each
Note:
Power handling measured using AES standards: transducer driven continuously for two
hours with a band limited noise signal having a 6 dB peak-average ratio.
AUDIO INPUT
Type
Differential, electronically balanced
Maximum Common
Mode Range
±15 V DC, clamped to earth for voltage transient protection
Connectors
Female XLR input with male XLR loop output
Input Impedance
10 k
differential between pins 2 and 3
Wiring
Pin 1: Chassis/earth through 220 k
, 1000 pF, 15 V clamp network to provide virtual ground lift at
audio frequencies
Pin 2:
Pin 3: Signal –
Case: Earth ground and chassis
DC Blocking
None on input; DC blocked through signal processing
CMRR
>50 dB, typically 80 dB (50 Hz – 500 Hz)
RF Filter
Common mode: 425 kHz
Differential mode: 142 kHz
TIM Filter
<80 kHz, integral to signal processing
Nominal Input Sensi-
tivity
0 dBV (1.0 V rms, 1.4 V peak) continuous is typically the onset of limiting for noise and music
Input Level
Audio source must be capable of pro20 dBV (10 V rms, 14 V peak) into 600
to produce
the maximum peak SPL over the operating bandwidth of the loudspeaker
AMPLIFIER
Type
Two-channel complementary MOSFET output stages (class AB/H)
Output Power
1240 W total (2 x 620 W)
Note:
Wattage rating based on the maximum unclipped burst sine-wave rms voltage the amplifier
will produce into the nominal load impedance; both channels 70 V rms (100 V peak) into 8 ohms.
Summary of Contents for X-800C
Page 6: ...CONTENTS vi ...
Page 12: ...CHAPTER 2 POWER REQUIREMENTS 12 ...
Page 20: ...CHAPTER 4 RMS REMOTE MONITORING SYSTEM 20 ...
Page 26: ...CHAPTER 6 X 800C SPECIFICATIONS 26 ...
Page 27: ......