9
MANUGENEX7xx - Version 2.12
© 2018-2022 EXOR International S.p.A. - Subject to change without notice
3 Technical Specifications
Electromagnetic Compatibility (EMC)
Radiated disturbance test
Class A
CISPR 22
CISPR 16-2-3
Electrostatic discharge immunity test
8 kV (air electrostatic discharge)
EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency,
80 MHz ÷ 1 GHz, 10V/m
EN 61000-4-3
electromagnetic field immunity test
1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
Burst immunity test
± 2 KV dc power port
EN 61000-4-4
± 1 KV signal line
Surge immunity test
± 0,5 KV dc power port (line to earth)
EN 61000-4-5
± 0,5 KV dc power port (line to line)
± 1 KV signal line (line to earth)
Immunity to conducted disturbances
inducted by radiofrequency field
0.15 ÷ 80 MHz, 10V
EN 61000-4-6
Power frequency magnetic field
immunity test
Enclosure, 50/60Hz, 30A/m
EN 61000-4-8
Environmental conditions
Operating temperature (surrounding
-20 ÷ +60°C (vertical installation)
EN 60068-2-14
air temperature)
Plug-in modules and USB devices
may limit max temperature to +50°C
Storage temperature
-20 ÷ +70°C
EN 60068-2-1
EN
60068-2-2
EN
60068-2-14
Operating and storage humidity
5 ÷ 85 % RH not-condensing
EN 60068-2-30
Vibrations
5 ÷ 9 Hz, 7 mm
p-p
EN
60068-2-6
9 ÷ 150 Hz, 1 g
Shock
± 50 g, 11 ms, 3 pulses per axis
EN 60068-2-27
Protection class
Front panel IP66, Rear IP20
EN 60529
Touchscreen technology
Projected capacitive
Back-up battery
3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse
Automatic
Serial Port
RS-232, RS-485, RS-422 software configurable
Flash
4GB for eX705, eX707, eX710, eX707G, eX710G,
8GB for eX712, eX715, eX721
RAM
512MB for eX705, 1GB for eX707, eX710, eX707G, eX710G,
2GB for eX712, eX715, eX721
Hardware clock
Clock/Calendar with back-up battery
Accuracy RTC (at 25°C)
<100ppm