4 .
UK - Product information
This original installation instruction contains no construction documentation .
The following symbols are used in the instructions to draw attention to the risk of danger or damage to the product .
Prohibited symbol
Failure to observe instructions marked with the prohibited symbol may result in ex-
treme danger .
Danger symbol
Failure to observe instructions marked with the prohibited symbol is associated with
the risk of injury or material damage .
Disposal
No special precautions . The product should be discarded in accordance with national
regulation for disposal of electronic waste .
4 .1
Package contents
1 pc . RBV1 .
1 pc . installation and operation instruction for the RBV1 .
4 .2
Function
Scope
The RBV1 is a fan for mounting on top of the chimney . The RBV1 is designed to facilitate ignition
and refueling . It is designed for wood burning on:
• Boiler (check with specialized dealer, if applicable)
• Stoves or closed inserts with a nominal effect of maximum 8 kW .
The RBV1 comes with a flexible flange, a 5-meter cord and an integrated isolation switch .
Function
The RBV1 has been developed to solve draught problems by creating a mechanical draught on
chimneys with circular core and a maximum internal diameter of ø220 mm . The RBV1 is designed
to withstand high temperatures associated with wood burning at a max . temperature of 250 °C
and tolerates continuous operation on stoves and closed inserts .
The RBV1 must always be on during start-up (lighting the fire) and during refueling . When the
operating temperature in the fireplace, flue and chimney has reached a reasonable level and thus
created sufficient draft, you may choose to switch off your RBV1 . If you need extra draw-out later,
due to e .g . a change in weather, you simply turn on the RBV1 again, leaving it active as long as
necessary .
Bad heating habits may result in problems, such as soot, chimney fires, etc ., which may damage the
RBV1 .
More information
www .exodraft .co .uk
WARNING
To avoid chimney fires – the chimney must be swept before mounting the RBV1!
As the RBV1 is part of a wood-fired installation, please ensure that the design meets the requirements
of fresh air supply . It is always recommend to install a smoke alarm in connection with a wood-fired
installation . Regardless of usage pattern, you must turn on your RBV1 at least once a month, allowing it
to run for 5-10 minutes . Inspect and clean your RBV1 installation at least once a year . The manufacturer
cannot be held responsible for water penetration into the chimney .
3200998-RBV1-DK-SE-NO-UK-DE-20180813
30
•
UK