- 39 -
h)
Check that the spark plug wire(s) are properly connected.
i)
Check for loose or faulty wiring connections. If it is necessary to disconnect
wire connectors,
Do Not
pull on the wires while disconnecting.
j)
Check for corrosion at all wiring connections. Even minor corrosion may
cause a faulty connection. Clean connector terminals thoroughly with
electrical contact cleaner, apply dielectric grease and reconnect.
IMPORTANT: It is essential that all operator safety mechanisms be
connected and in proper operating condition prior to mower use.
NOTE: After carefully checking the above steps, attempt to start the engine. If
it does not start, contact your authorized Exmark service dealer.
ENGINE TROUBLESHOOTING
When a problem occurs, do not overlook the simple causes. For example, starting
problems could be caused by an empty fuel tank.
The following table lists some of the common causes of trouble.
Do not attempt to service or replace major items or any items that call for special
timing or adjustment procedures (such as valves, governor, etc.). Have this work
done by your
Engine Service Dealer.
ENGINE TROUBLESHOOTING TABLE
PROBLEM
NO
FUEL
IMPROPER
FUEL
DIRT IN
FUEL LINE
DIRTY AIR
FILTER
FAULTY
SPARK
PLUG
ENGINE
OVERLOADED
BLOCKED
FUEL
FILTER
INCORRECT
OIL
LEVEL
DIRTY
AIR
SCREEN
Will not start
X
X
X
X
X
X
Hard starting
X
X
X
X
X
X
X
Stops suddenly
X
X
X
X
X
X
X
Lacks power
X
X
X
X
X
X
X
X
Operates erratically
X
X
X
X
X
X
X
Knocks or pings
X
X
X
Skips or misfires
X
X
X
X
X
Backfires
X
X
X
X
X
Overheats
X
X
X
X
X
High fuel
consumption
X
X
X
X
Summary of Contents for Turf Tracer HP TT3615KA
Page 1: ......
Page 45: ... 40 8 WIRING DIAGRAMS ...
Page 46: ... 41 9 HYDRAULIC DIAGRAM ...
Page 49: ... 44 NOTES ...
Page 50: ... 45 SERVICE RECORD Date Description of Work Done Service Done By ...