Exide 12/7 User Manual Download Page 9

9

TEchnIcAL SpEcIfIcATIonS

Model: 

EXIDE 12/7

EXIDE 12/7 is a primary-switched computer-controlled charger

Input voltage 

 

220-240 VAC +/-10% 

Input current 

 

1,5 A

Back current 

 

≤1mA 

Charging current 

 

13,7 – 15,5 VDC at 25ºC 

Charging current Supply 

 

13,7 VDC

Charging current 

 

Max 7 A 

Ripple voltage 

 

Max 70 mV 

Ambient temperature 

 

- 40  –  + 50ºC

Cooling

 

Convection

Type of charge 

 

5 step IUIU + pulse

 

Or 13,7 V (Maintenance charge)

Lead-acid battery types 

 

AGM/GEL, standard batteries

Battery capacity 

 

1 – 150 Ah (Max 180 Ah)

Cabling 

Battery cable  1700 mm
Power cable  2x0,75 mm

2  

1800 mm

Dimensions (LxWxH)

 

225x50x50 mm

International Protection rating 

  IP54

Weight 

 

0,5 kg

cE mAnUfAcTURER’S DEcLARATIon

Manufacturer: EXIDE Technologies, Kungälv, Sweden  
and Primepower AB, Växjö, Sweden
Product: Battery charger EXIDE 12/7
The manufacturer guarantees that the  
unit complies with the relevant standards.

Tested and approved by Intertek Semko.
www.exide.nu   www.tudor.se

Summary of Contents for 12/7

Page 1: ...1 USER GUIDE 12 V Lead acid batteries 1 150 Ah GB ...

Page 2: ...an be stored in its packaging so that you protect the charger keep cables tidy keep the user guide safe and at the same time protect the environment Discarded packaging can be recycled Read the safety instructions and user guide carefully If you follow the instructions you will benefit from a high performance charger that will give excellent service for many years to come For more information abou...

Page 3: ...pply mode the charger acts as a power supply and gives a continual power supply of max 7 A at 13 7 V MP Supply 13 7V Standard AGM GEL 1 19Ah 20 59Ah 60 150Ah MP Supply 13 7V Standard AGM GEL 1 19Ah 20 59Ah 60 150Ah 1 Connect the charger s mains plug to a power socket 2 Connect the charger s red cable clamp to the battery s positive ter minal post and the black cable clamp to the battery s negative...

Page 4: ...shing and will change to a constant yellow At the same time the lamp on the front of the charger will go out 6 The LED will be a constant yellow until the charge is complete when the LED changes from yellow to green In the 13 7 V Supply mode the green lamp illuminates while the function is connected 7 Following completion of the charge the charger cables can either be removed from the terminals or...

Page 5: ...e charger provides a constant output voltage of 13 7 V that in certain circumstances may cause sparking Be very careful with polarity when using the unit as a power supply Fix the clamps onto the battery poles before plugging the unit into the mains supply Also remember when using the power supply function that you must unplug the unit from the mains before removing the terminal clamps from the ba...

Page 6: ...ificant for batteries ability to receive charge The thermal sensor is integrated in one of the terminal clamps Thanks to our temperature compensation the common problems involved in insufficient charging in cold weather and overcharging at high temperatures are eliminated The charging curve is shown on the accompanying diagram which shows how the charge is split into five different steps that are ...

Page 7: ...The red LED lights the yellow LED flashes and charging is terminated Probable cause 1 The battery has a fault that does not permit it to be charged e g a short circuit Action Replace the battery Fault Charging does not start i e the lamp continues to shine and the LED does not change to the constant yellow light Probable cause The battery voltage is too low to start the char ger This may be becaus...

Page 8: ...reasons Action If possible disconnect the parallel load and repeat charg ing or purchase a larger charger suitable for both charge and drain Probable cause 3 Battery is too large The battery is larger than the recommended size for the charger which means that the charge could not be completed within the time constraints that are built into the battery for safety reasons Action Repeat charging Prob...

Page 9: ...tep IUIU pulse Or 13 7 V Maintenance charge Lead acid battery types AGM GEL standard batteries Battery capacity 1 150 Ah Max 180 Ah Cabling Battery cable 1700 mm Power cable 2x0 75 mm2 1800 mm Dimensions LxWxH 225x50x50 mm International Protection rating IP54 Weight 0 5 kg CE Manufacturer s declaration Manufacturer EXIDE Technologies Kungälv Sweden and Primepower AB Växjö Sweden Product Battery ch...

Page 10: ...nufacture or distribution the mandatory guarantee rights apply The guarantee will no longer be valid if the charger has not been handled correctly or opened or repaired by any other than Exide Technologies or its authorized representatives Exide Technologies is not responsible for other costs than those stated above i e no potential consequential costs Nor is Exide Technologies liable under any ot...