background image

6

DEScRIpTIon of fUncTIonS

The charger is fully automatic and programmed for advanced 
charging of lead-acid batteries between 1 and 150 Ah. The 
integrated safety functions that are intended to limit overcharging 
could interrupt the charge process when charging larger batteries. 
This applies especially when charging batteries that are larger than 
approx. 180 Ah.

The unit can be used both as a battery charger and power supply. 
The power supply is activated by selecting 13.7 V Supply, which 
provides a constant 13.7 V voltage at max. 7 A. The mode is also 
used for maintenance charging 12 V batteries.

This product is equipped with a temperature compensator, 
because temperature is highly significant for batteries’ ability to 
receive charge. The thermal sensor is integrated in one of the 
terminal clamps. Thanks to our temperature compensation, the 
common problems involved in insufficient charging in cold weather 
and overcharging at high temperatures are eliminated.

The charging curve is shown on the accompanying diagram,  
which shows how the charge is split into five different steps  
that are adapted to the battery type and size. 

The charger must be connected to the battery as described in 
‘getting started’. After it is connected, it will charge the battery and 
maintain it fully charged as long as it is connected to the mains 
power. In order to minimise the risk of overcharging an incorrect 

I (A)

(h)

STEP

1

STEP

2

STEP

3

STEP

4

STEP

5

U (V)

Volt (V) standard battery (wet flooded)
Volt (V) AGM/GEL battery 

Ampere (A) standard battery (wet flooded)
Ampere (A) AGM/GEL battery 

Continues on next page.

Summary of Contents for 12/7

Page 1: ...1 USER GUIDE 12 V Lead acid batteries 1 150 Ah GB ...

Page 2: ...an be stored in its packaging so that you protect the charger keep cables tidy keep the user guide safe and at the same time protect the environment Discarded packaging can be recycled Read the safety instructions and user guide carefully If you follow the instructions you will benefit from a high performance charger that will give excellent service for many years to come For more information abou...

Page 3: ...pply mode the charger acts as a power supply and gives a continual power supply of max 7 A at 13 7 V MP Supply 13 7V Standard AGM GEL 1 19Ah 20 59Ah 60 150Ah MP Supply 13 7V Standard AGM GEL 1 19Ah 20 59Ah 60 150Ah 1 Connect the charger s mains plug to a power socket 2 Connect the charger s red cable clamp to the battery s positive ter minal post and the black cable clamp to the battery s negative...

Page 4: ...shing and will change to a constant yellow At the same time the lamp on the front of the charger will go out 6 The LED will be a constant yellow until the charge is complete when the LED changes from yellow to green In the 13 7 V Supply mode the green lamp illuminates while the function is connected 7 Following completion of the charge the charger cables can either be removed from the terminals or...

Page 5: ...e charger provides a constant output voltage of 13 7 V that in certain circumstances may cause sparking Be very careful with polarity when using the unit as a power supply Fix the clamps onto the battery poles before plugging the unit into the mains supply Also remember when using the power supply function that you must unplug the unit from the mains before removing the terminal clamps from the ba...

Page 6: ...ificant for batteries ability to receive charge The thermal sensor is integrated in one of the terminal clamps Thanks to our temperature compensation the common problems involved in insufficient charging in cold weather and overcharging at high temperatures are eliminated The charging curve is shown on the accompanying diagram which shows how the charge is split into five different steps that are ...

Page 7: ...The red LED lights the yellow LED flashes and charging is terminated Probable cause 1 The battery has a fault that does not permit it to be charged e g a short circuit Action Replace the battery Fault Charging does not start i e the lamp continues to shine and the LED does not change to the constant yellow light Probable cause The battery voltage is too low to start the char ger This may be becaus...

Page 8: ...reasons Action If possible disconnect the parallel load and repeat charg ing or purchase a larger charger suitable for both charge and drain Probable cause 3 Battery is too large The battery is larger than the recommended size for the charger which means that the charge could not be completed within the time constraints that are built into the battery for safety reasons Action Repeat charging Prob...

Page 9: ...tep IUIU pulse Or 13 7 V Maintenance charge Lead acid battery types AGM GEL standard batteries Battery capacity 1 150 Ah Max 180 Ah Cabling Battery cable 1700 mm Power cable 2x0 75 mm2 1800 mm Dimensions LxWxH 225x50x50 mm International Protection rating IP54 Weight 0 5 kg CE Manufacturer s declaration Manufacturer EXIDE Technologies Kungälv Sweden and Primepower AB Växjö Sweden Product Battery ch...

Page 10: ...nufacture or distribution the mandatory guarantee rights apply The guarantee will no longer be valid if the charger has not been handled correctly or opened or repaired by any other than Exide Technologies or its authorized representatives Exide Technologies is not responsible for other costs than those stated above i e no potential consequential costs Nor is Exide Technologies liable under any ot...