Technical data

Height x width x depth

: 125 mm x 175 mm x 75 mm

Degree of protection/material

: IP54/ABS

Supply voltage

: 230V +/-10%

Fuse

: T5A

Ambient temperature

: -20°C - +50°C

Boiler thermostat input

: 10-230V AC/DC

Boiler output relay

: max. 8A/230V

Chimney fan output (AC3)

: max. 3A/230V

EXHAUSTO A/S
Odensevej 76 
DK-5550  Langeskov
Tel.: +45 6566 1234
Fax: +45 6566 1110
E-mail: [email protected]
www.exhausto.com

EXHAUSTO GmbH
Am Ockenheimer Graben 40
D-55411  Bingen-Kempten
Tel.: +49 6721 9178-0
Fax: +49 6721 9178-99
E-mail: [email protected]
www.exhausto.de

EXHAUSTO NORGE A/S
Enebakkveien 117
N-0680  Oslo
Tel.: +47 2268 9006
Fax: +47 2268 0384
E-mail: [email protected]
www.exhausto.com

EXHAUSTO Ltd.
4/5 Centurion Court, 
Brick Close, Kiln Farm
GB-Milton Keynes MK11 3JB
Tel.: +44 1908 261196
Fax: +44 1908 261186
E-mail: [email protected]

EXHAUSTO AB
Verkstadgatan 13
S-542 22  Mariestad
Tel.: +46 501 13750
Fax: +46 501 12500
E-mail: [email protected]
www.exhausto.com

EXHAUSTO Inc.
8601 Dunwoody Place
Suite 450
Atlanta, GA 30350 USA
Tel.: +1 770 587 3238
Fax: +1 770 587 4731
E-mail: [email protected]
www.exhausto.com

Summary of Contents for EBC11

Page 1: ...EXHAUSTO 3001414 2000 02 01 fm 1 8 44 GB...

Page 2: ...veloped to meet BS 5440 Part 1 1990 and BS 6644 1991 and other relevant European standards Functions When the boiler thermostat calls for heat the chimney fan will immediately start up on full speed W...

Page 3: ...t 1 Opto coupler 10 230V 6 7 Boiler thermostat 1 Opto coupler 10 230V 8 24V DC supply for voltage free contact 9 LK0V DC supply for voltage free contact 10 Boiler thermostat 2 Opto coupler 10 230V 11...

Page 4: ...connected over terminals 1 3 Connection to the boiler control Step 1 The normal start signal for the burner phase is connected to terminal 6 Loop terminals 7 and 14 The start signal for the boiler com...

Page 5: ...cted over to terminal 6 Loop terminals 7 and 14 The start signal for the boiler comes on from terminal 15 Connect neutral from the timer to terminal 4 Neutral for the boiler can be taken from ter mina...

Page 6: ...egistered click sound or the light Fig 6 D goes out Register the PDS value of disengagement Set the PDS to 25 Pa below the registered value of disengagement 7 2 step systems Start step 2 on the system...

Page 7: ...SEE THE WARNING Permanent light in ALARM diode Fig 7 A The chimney fan light is on FAN Fig 7 D Failing chimney draught 1 If PDS light is on Fig 7 E press the RESET but ton for one second Fig 7 B PLEA...

Page 8: ...Graben 40 D 55411 Bingen Kempten Tel 49 6721 9178 0 Fax 49 6721 9178 99 E mail exhausto sparkasse net www exhausto de EXHAUSTO NORGE A S Enebakkveien 117 N 0680 Oslo Tel 47 2268 9006 Fax 47 2268 0384...

Reviews: