18
0x50
SAMPLE_RATE
1
u8
Selects the frequency of packets (samples) sent to the host
0x00
= 200 Hz (100 Hz if a packet with
orientation
is chosen)
0x01
= 100 Hz
0x02
= 50 Hz
0x03
= 33.33 Hz
0x04
= 25 Hz
0x05
= 20 Hz
0x06
= 16.67 Hz
0x07
= 12.5 Hz
0x08
= 10 Hz
0x09
= 5 Hz
0x0A
= 300 Hz (No magnetometer data, 100 Hz if a packet with
orientation
is chosen)
0x51
STREAM_LOG
1
U8
Select the Stream and or Log Mode when START command is issued
0x00
= Stream packets via bluetooth
0x01
= Log packets on file in the EXLs3’s internal flash disk
0x02
= Stream & Log packets
0x52
SWRFD
1
U8
Start When Removed From Dock
mode
0x00
= data streaming and/or logging begins immediately after START
command has been sent
0x01
= data streaming and/or logging begins immediately after START
command has been sent only if the EXLs3 is not powered by the docking
station, otherwise it waits the dock’s power supply being removed before
starting streaming/logging.
When the EXLs3 is put back in the docking station and the power supply is
restored, it
stops
streaming/logging
This behavior can be used to synchronize the start/stop time of several
sensors.
0x02
= continuous data logging when the EXLs3 is not powered by the
docking station, without start/stop commands. In this operating mode no
Bluetooth connection is required.
0x53
WAKEUP_MODE
1
U8
*Only available on EXLs3 with vibration sensor.
It configure the device’s wake-up mode
0x10
= BUTTON: the device switches-on by pressing the button
0x20
= VIBRO_FAST: the device switches-on with vibration (High
sensitivity).
0x21
= VIBRO_MED: the device switches-on with vibration (Medium
sensitivity).
0x22
= VIBRO_SLOW: the device switches-on with vibration (Low
sensitivity).
0x30
= BUTTON + VIBRO_FAST: the device switches-on with vibration
(High sensitivity) or by button.
0x31
= VIBRO_MED: the device switches-on with vibration
(Medium sensitivity) or by button.
0x32
= BUTTON + VIBRO_SLOW: the device switches-on with vibration
(Low sensitivity) or by button.