EXCELL PRECISION CO., LTD.
02018058
16
ZSME300000317
RS-232 Interface Format
I . Mode
:
UART Signal of EIA-RS0232 C
II . Format
:
1. Baud rate
:
1 200, 2 400, 4 800, 9 600 bits/second
2. Data bits
:
8 bits
3. Parity bit
:
None
4. Stop bits
:
1 bit
5. Code
:
ASCII (Exchange code of American standard)
Start bit Data bits Stop bit
RS-232 Data Format
Stable transmission (
), Continuous transmission (
),
Press
key to transmit ( )
9. gram as weight unit
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 g
HEAD , HEAD , ± DATA UNIT CR LF
10. kg or lb as weight unit
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
18
kg/lb
HEAD , HEAD , ± DATA UNIT CR LF
11. lb.oz as weight unit
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
20 21 Lb.oz
HEAD , HEAD , ± DATA UNIT CR LF
12. HK tael as weight unit
1 2 3 4 5 6
7 8 9 10 11 12 13 14 15 16 17 18 19
20 HK
tael
HEAD , HEAD ,± DATA UNIT CR LF
13. viss as weight unit
1 2 3 4 5 6
7 8 9 10 11 12 13 14 15 16 17 18 19
20 viss
HEAD ,
HEAD
,
±
DATA UNIT
CR LF
Summary of Contents for ZSME300000317