![Excell HJW User Manual Download Page 22](http://html1.mh-extra.com/html/excell/hjw/hjw_user-manual_2449505022.webp)
EXCELL PRECISION CO., LTD
02022010
ZSME300000197
20
When the right digit is flashing,
press TARE/PT
key while
there is no load on platter
kg
Put the calibrated weight on
platter and press TARE/PT key;
After 3 beep sounds, calibration
completes;
Remove weight
.
kg
Press NET/GROSS
key
to skip
Press
NET/GROSS
key
to move the flashing
digit to the left.
About 2 seconds later
Press NET/GROSS
key to exit
About 2 seconds later
2-2 External Weight Calibration
The conditions for external weight calibration:
The calibration weight value placed on the platter must be over 100e, and the standard
deviation of the weight must be within 10%.
This function is not available for approval models.
.
.
.
ON/ZERO
key
Upward key (0~ 9 digit entry )
UNIT
key
Downward key (0,9~1 digit entry)
TARE/PT
key
Move cursor rightward
NET/GROSS
key
Move cursor left ward
Press TARE/PT
key, the display
shows the calibration value. The
right digit keeps flashing.
The calibration value could
be changed
kg
Reading Zero
kg
Summary of Contents for HJW