02027011 ZSME300000342
11
EXCELL PRECISION CO., LTD.
Compound key
+
:
Only when it is set“ON”in Hold function, press these 2 keys together to call
up Hold function.
+
:
Press these 2 keys together to call up Hi/Lo/Ok setting.
+
:
Press these 2 keys together to clear the accumulation data when there is
no weight in accumulation mode. M+
indication “
”disappears.
High Resolution
:
Press key for 3 seconds to shift to high resolution display. And it
returns to original resolution after release key for 3 seconds.
1-7 Error Messages
The EEPROM is not working correctly. (EEPROM is missing or circuit neaby
EEPROM is damaged.)
Zero is higher than the zero range when switching the indicator on.
Zero is lower than the zero range when switching the indicator on.
ADIC value is over the maximum range.
The weight of the object is over 9 divisions of the maximum capacity.
The weight of the object is under -1/6 maximum capacity.
1-8 Available Units
kg
1 g = 0.001 kg
g
1 g = 1 g
lb
1 g = 0.002204623 lb
lb,oz
1 g = 0.03527396 oz
Taiwan Tael
1 g = 0.02666667 Tael
H.K. Tael
1 g = 0.02645546 Tael
viss
1 kg = 0.612245 viss
1-9 Firmware Version
When power is off, hold key and press key to wait till display shows 01 AdC and
then press key twice to enter 03 VEr. Press key and displays firmware version
02027 and then press key to display maintenance number 011 for 2 secs. Press
key to back to last screen and displays 03 VEr.