Excell 20key-6PS User Manual Download Page 4

 

 

 

                                                                                                                     

                 

   

 

2

EXCELL PRECISION CO., LTD.

 

01008044

 

ZSME100000109 

 

 

 

 

 

Instruction for Use 

1. In order to prevent the scale from dust and static electricity, please fix the dustproof 

cover on the scale with double-sided adhesive. 

2. The scale should not be drenched by rain or water. (If it gets wet carelessly, please 

wipe it dry with a cloth. If its operation is abnormal, please send it to our distributor for 

service. ) 

3. Please keep the scale in a cool and dry place. Do not store at high temperatures or 

damp places. 

4. Please keep the scale clean and free from insect infestation. 

5. To avoid impact and it is to be used under designated pressure (the weight put on the 

platter can not exceed the maximum capacity of the scale). 

6. If the scale is not going to be used for some time, please clean it and store it in a plastic 

bag in dry condition. A desiccant sachet may be included to prevent moisture build up. 

The scale should be recharged every 3 months to prevent failure of the internal 

rechargeable battery. 

7. The commodity should be placed in the center of platter for accurate weighing. The 

dimension of the weighted commodity should not exceed the dimension of platter. 

8. Please release the protection screw “

4

” before weighing. 

9. Please operate or charge the scale in an open area. Do not squeeze the power cord to 

avoid wire on fire. 

10.  Operating temperature: -10

 ~ + 40

 

11.  Any suggestion for product is welcomed. 

Preparation Before Using 

1.  Put the scale on a firm level surface free for accurate weight readings. Adjust the four 

leveling feet to get the leveling bubble at the centre of circle. 

2. Scale must be used under a stable temperature and stable air flow. Avoid direct 

sunlight onto the scale or near the exhaust port of ventilating system.   

3. Scale must be used under individual socket to avoid the interference of other electric 

appliances. 

4.  Remove any weight that might be on the platter before the scale is switched on.   

5. Please note that when      or        symbol appears on the screen, the scale needs

 

to 

be charged. 

6.   Introduction of Storage Battery 

Thank you for purchasing Price Computing Scale. In order to 

operate smoothly, to last the durability, and to reduce the chance 

of breakdown for this product, please read this Manual carefully. 

Summary of Contents for 20key-6PS

Page 1: ...erein is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permissio...

Page 2: ......

Page 3: ...ER SUPPLY 5 CHAPTER 2 KEYBOARD FUNCTION 6 CHAPTER 3 OPERATION INSTRUCTION 7 3 1 INTERNAL VALUE DISPLAY MODE 7 3 2 SETTING UP BACKLIGHT MODE OPTION 7 3 3 SETTINGS OF PRICING UNIT 7 3 4 6 PRSET OPERATIN...

Page 4: ...d be placed in the center of platter for accurate weighing The dimension of the weighted commodity should not exceed the dimension of platter 8 Please release the protection screw 4 before weighing 9...

Page 5: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized pe...

Page 6: ...9 division of maximum capacity Zero value above 10 full scale Zero value below 10 full scale the internal value is over 350 000 the internal value is below 80 000 If the negative weight is over 20 di...

Page 7: ...rge Voltage 1 AC 110 V 10 15 2 AC 220 V 10 15 Power Consumption 30 mA system no backlight About 140 hours 40 mA system front display backlight About 100 hours 50 mA system front display backlight rear...

Page 8: ...e unit price has been input for 3 seconds you can input the new one immediately 1T1 Press the key to deduct the containers weight and the symbol in Weight will appear 1Z1 Weight return to zero P1 P5 P...

Page 9: ...backlight off mode Auto backlight mode When there is a weight on the pan which weight is over 10d or pressing any keys the backlight will be on After back to zero for 10 desonds the weight is under 1...

Page 10: ...P5 Weight Unit Price Total 0 000 0 00 0 00 1 Both the scale is empty and there is weight on are ok 2 0 000 1 23 0 00 Press P1 P5 you can call input unit price 2 2 P6 Calling Preset Unit Price After pr...

Page 11: ...keys to choose 0 1 2 3 in order 0 9600 bits second 1 4800 bits second 2 2400 bits second 3 1200 bits second Press T key to enter the next setting mode Press P2 key to save setting values The scale wi...

Page 12: ...000 7 Stable transmission printing format 001 000 8 Command mode Press T the next setting mode Press P2 to save setting values The scale will count backwards to zero and back to weight mode When F2 s...

Page 13: ...ight unit is g lb or oz 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 twg HEAD HEAD DATA UNIT CR LF 4 Weight unit is Catty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Catty HEAD HEAD DA...

Page 14: ...0A HEAD HEAD DATA UNIT C LF 2 The net weight 1 568lb shows as below after unstable under tare or pre tare mode U S N T 0 0 1 5 6 8 l b 0D 0A HEAD HEAD DATA UNIT C LF 3 The net weight 15 TW Catty and 6...

Page 15: ...EXCELL PRECISION CO LTD 01008044 ZSME100000109 Appendix 7 Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M...