8
EXCELL PRECISION CO., LTD.
01008044
ZSME100000109
3-4 6 Prset Operating Instruction
1. Preset Mode
1.1 Preset Unit Price (P1-P5 Preset mode)
Weight
Unit
Price
Total
0.000 0.00
0.00
1
Both the scale is empty and there is weight on are ok
2 0.000
1.23
0.00
Input the unit price you need by pressing number key [0]-[9] in Unit Price
3
Press ”
” after inputing unit price
,
and then press any key of [P1]-[P5]
,
the
input unit price will be recorded in the corresponding place
1.2 P6 Preset Unit Price Mode
After the above 2 of 1.1,press ”
” then press P6
,
if the number key 00~79 are not
input within 2 seconds
,
memory P6 directly
;
If the any group of number key 00~79 are
input within 2 seconds
,
the unit price will be recordedin the place you need.
2. Calling Preset Unit Price Mode
2.1 Calling Preset Unit Price (P1-P5)
Weight
Unit
Price
Total
0.000
0.00
0.00
1
Both the scale is empty and there is weight on are ok
2 0.000
1.23
0.00
Press [P1]-[P5] you can call input unit price
2.2 P6 Calling Preset Unit Price
After pressing P6
,
if the number key 00~79 are not input within 2 seconds
,
the unit
price of P6 is called directly
;
If the any group of number key 00~79 are input within 2
seconds, the unit price of this group is called.
3-5 External Weight Calibration
Steps
:
1. Make sure the scale backs to zero and is in “kg” mode.
2. Press
P5
key and do not release, the then press
↵
key to show
“
” , the weight display “ .
” kg .
3. Release two keys.
4. Key-in pre-calibration weight, the display will show “pre-calibration” of
weight value in flash. Place full weight(s) on the pan. When the scale is
stable, take off the weight(s) from the pan. The calibration finished.
3-6 Factory Default Setting
To Return to the factory setting, hold P5 key and press CE key.
After buzzer beep sound, release two keys.
The scale will return to factory setting.