Excell 20key-6PS User Manual Download Page 10

 

 

 

                                                                                                                     

                 

   

 

8

EXCELL PRECISION CO., LTD.

 

01008044

 

ZSME100000109 

3-4 6 Prset Operating Instruction 

1. Preset Mode 
1.1 Preset Unit Price (P1-P5 Preset mode) 

  

Weight 

Unit 

Price 

 

Total 

 

0.000 0.00

0.00

 

Both the scale is empty and there is weight on are ok 

2 0.000 

1.23

0.00

 

Input the unit price you need by pressing number key [0]-[9] in Unit Price 

Press ”

” after inputing unit price

and then press any key of [P1]-[P5]

the 

input unit price will be recorded in the corresponding place 

1.2 P6 Preset Unit Price Mode 

After the above 2    of 1.1,press ”

”  then press P6

if the number key 00~79 are not 

input within 2 seconds

memory P6 directly 

If the any group of number key 00~79 are 

input within 2 seconds

the unit price will be recordedin the place you need.   

2.  Calling Preset Unit Price Mode 
2.1 Calling Preset Unit Price (P1-P5) 

  

Weight 

Unit 

Price 

Total 

 

 0.000 

0.00

0.00  

 

Both the scale is empty and there is weight on are ok 

 

 

2 0.000 

1.23

0.00

 

 

Press [P1]-[P5] you can call input unit price   

2.2 P6 Calling Preset Unit Price 

After pressing P6

if the number key 00~79 are not input within 2 seconds

the unit 

price of P6 is called directly 

If the any group of number key 00~79 are input within 2 

seconds, the unit price of this group is called. 

3-5 External Weight Calibration   

      Steps

  1. Make sure the scale backs to zero and is in “kg” mode. 

 

 

 

2. Press 

 

P5

 

  key and do not release, the then press 

 key to show 

 “   

    ” , the weight display “ .  

 

” kg .   

                        3. Release two keys. 

                            4. Key-in pre-calibration weight, the display will show “pre-calibration” of 

weight value in flash.    Place full weight(s) on the pan.    When the scale is 
stable, take off the weight(s) from the pan. The calibration finished. 

3-6 Factory Default Setting   

             

To Return to the factory setting, hold  P5  key and press  CE  key.  

        After buzzer beep sound, release two keys.     

        The scale will return to factory setting. 

Summary of Contents for 20key-6PS

Page 1: ...erein is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permissio...

Page 2: ......

Page 3: ...ER SUPPLY 5 CHAPTER 2 KEYBOARD FUNCTION 6 CHAPTER 3 OPERATION INSTRUCTION 7 3 1 INTERNAL VALUE DISPLAY MODE 7 3 2 SETTING UP BACKLIGHT MODE OPTION 7 3 3 SETTINGS OF PRICING UNIT 7 3 4 6 PRSET OPERATIN...

Page 4: ...d be placed in the center of platter for accurate weighing The dimension of the weighted commodity should not exceed the dimension of platter 8 Please release the protection screw 4 before weighing 9...

Page 5: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized pe...

Page 6: ...9 division of maximum capacity Zero value above 10 full scale Zero value below 10 full scale the internal value is over 350 000 the internal value is below 80 000 If the negative weight is over 20 di...

Page 7: ...rge Voltage 1 AC 110 V 10 15 2 AC 220 V 10 15 Power Consumption 30 mA system no backlight About 140 hours 40 mA system front display backlight About 100 hours 50 mA system front display backlight rear...

Page 8: ...e unit price has been input for 3 seconds you can input the new one immediately 1T1 Press the key to deduct the containers weight and the symbol in Weight will appear 1Z1 Weight return to zero P1 P5 P...

Page 9: ...backlight off mode Auto backlight mode When there is a weight on the pan which weight is over 10d or pressing any keys the backlight will be on After back to zero for 10 desonds the weight is under 1...

Page 10: ...P5 Weight Unit Price Total 0 000 0 00 0 00 1 Both the scale is empty and there is weight on are ok 2 0 000 1 23 0 00 Press P1 P5 you can call input unit price 2 2 P6 Calling Preset Unit Price After pr...

Page 11: ...keys to choose 0 1 2 3 in order 0 9600 bits second 1 4800 bits second 2 2400 bits second 3 1200 bits second Press T key to enter the next setting mode Press P2 key to save setting values The scale wi...

Page 12: ...000 7 Stable transmission printing format 001 000 8 Command mode Press T the next setting mode Press P2 to save setting values The scale will count backwards to zero and back to weight mode When F2 s...

Page 13: ...ight unit is g lb or oz 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 twg HEAD HEAD DATA UNIT CR LF 4 Weight unit is Catty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Catty HEAD HEAD DA...

Page 14: ...0A HEAD HEAD DATA UNIT C LF 2 The net weight 1 568lb shows as below after unstable under tare or pre tare mode U S N T 0 0 1 5 6 8 l b 0D 0A HEAD HEAD DATA UNIT C LF 3 The net weight 15 TW Catty and 6...

Page 15: ...EXCELL PRECISION CO LTD 01008044 ZSME100000109 Appendix 7 Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M...

Reviews: