Mounting the System Controller 

The SC0750, SC1000 and SC2000 share the same mechanical chassis, while the SC3000 has a slightly larger 
mechanical enclosure.  However, the mounting instructions apply equally to all models with the exception of 

mounting hole locations.  

It is recommended that the System Controller be carried by holding the unit on two opposite sides, with 

fingers supporting the underside of the unit. During installation, the unit is light enough to be balanced in one 
hand, leaving the other hand free for inserting mounting screws. If access is restricted or the installer prefers 

a different approach, supporting the underside of the unit at approximately the level height of the installation 
location using a suitable mechanical prop would also suffice. 

While the System Controller can be left as a free-standing unit, it is intended to be easily installed in well-
ventilated 19” rack-mounting. It is recommended that the System Controller be installed with the text on the 

labels oriented the right way up. 

To install the System Controller in a 19” rack: 

1.

 

Disconnect any electrical cables that are connected to the main chassis. 

2.

 

Remove the two mounting brackets from the polythene bag. 

3.

 

Locate the four screws on the sides of the enclosure towards the front and remove. 

4.

 

The mounting bracket has two slots and two holes. The holes are intended for attachment of the 
brackets to the main chassis. Using two of the removed screws, attach the mounting bracket to the side 

of the enclosure. 

5.

 

Using the two remaining screws, repeat step 4 for the other side of the enclosure. The enclosure is now 

ready to be mounted in the rack.  

6.

 

Identify a screw-hole pair in the rack that lines up with the holes in the mounting brackets and using a 
screw-type compatible with the rack threading (usually #10-32 (imperial) or M4 (metric)), thread a 

single screw into one of the two holes and tighten by hand. 

7.

 

Supporting the foremost underside of the unit, move to the other side of the chassis and level the front 

of the enclosure. Insert another screw into one of the two holes and tighten by hand. 

8.

 

Move the support to the rear of the enclosure and raise the support until the front-back direction is 

level. Insert an additional screw into the mounting bracket on each side. The unit should now be in 
approximately the final intended lateral position. 

9.

 

Adjust the position of the unit (if necessary) to finalize location. The mounting bracket face that mates 
with the rack is slotted to allow some adjustment. 

10.

 

When satisfied with the position, tighten the four mounting screws using a screwdriver. Do not over-

tighten as this may strip the threading in the rack and render the mounting location useless. 

Note: 

The mounting brackets are designed to support the mechanical load of the System Controller chassis 

only. They are not designed to support any additional weight placed onto the top of the unit. Placing 
additional mechanical loading onto the unit may damage the mounting brackets, the racking or the 

mounting screws themselves. 

Excelitas Technologies considers evidence of such cases as outside of 

warranty.

 

It is recommended that both AC and DC-side cabling be tied off and mechanically supported to prevent 
undue stress on the electrical connectors. 

Warning: This device includes a circuit breaker located on the rear panel, do not position the 

equipment so that it is difficult to operate the disconnecting device 

Summary of Contents for 019-00186R

Page 1: ...following System Controller models Model Part Numbers SC0750 019 00199R SC1000 019 00186R SC2000 019 00211R SC3000 019 00213R Installation Reference Guide Excelitas Canada Inc 2260 Argentia Road Miss...

Page 2: ...any language in and form by any means without the prior written consent of Excelitas Canada Inc every effort has been made to ensure information in this manual is accurate however information in this...

Page 3: ...035 xxxxxR rev 1 035 00539R rev 2 035 xxxxxR rev 1 iii 035 00539R rev 5 Revision History Revision Comments Rev 1 0 Initial release Rev 2 0 Updated corporate logo minor edits corrections Rev 3 0 Added...

Page 4: ...rical Connectivity 8 6 Troubleshooting 9 7 Care and Maintenance 11 8 Technical Specifications 12 8 1 Environmental and Unit Specifications 12 8 2 Regulatory Compliance 12 8 3 China RoHS 13 8 4 WEEE Di...

Page 5: ...integrated electrical circuit breaker provides electrical fault protection and isolation while a front mounted on off switch and power indicator provides users with a simple easy to access means of po...

Page 6: ...been designed for safe use however if the equipment is used in a manner not specified by the manufacturer the protection systems provided by the equipment may be impaired The safety of any system inc...

Page 7: ...acles in the destination country A small polythene bag containing mounting brackets x2 Documentation CD Depending on the exact order the package may also contain a DC power cable Carefully remove the...

Page 8: ...m Controller is set to the off position 3 Locate the AC power cord and insert into the AC inlet receptacle on the rear of the System Controller 4 Locate the pair of 5W5 DC power connectors on the rear...

Page 9: ...inlet receptacle 10 Using the power switch on the front of the System Controller power on the connected AC series UV LED equipment When the outputs are live a green LED status indicator on the front...

Page 10: ...two remaining screws repeat step 4 for the other side of the enclosure The enclosure is now ready to be mounted in the rack 6 Identify a screw hole pair in the rack that lines up with the holes in the...

Page 11: ...tas com omnicure Excelitas Canada Inc 2021 All rights reserved 035 xxxxxR rev 1 035 00539R rev 2 035 xxxxxR rev 1 7 035 00539R rev 5 5 1 Mechanical Dimensions Figure 3 SC0750 SC1000 SC2000 Mechanical...

Page 12: ...Power Connectors x2 Figure 5 Power Connector looking at System Controller PIN Name Description A1 ve 48V DC power feed A2 ve 48V DC power feed SC2000 SC3000 only Shared current through this pin A3 ve...

Page 13: ...o be running at a reduced intensity Verify that the AC mains voltage for the SC0750 and SC1000 is within the range of 100 240V AC 50 60Hz Of particular concern is the low end AC voltage Verify that th...

Page 14: ...R rev 1 035 00539R rev 2 035 xxxxxR rev 1 10 035 00539R rev 5 Caution It is normal for electrical cables and connectors to warm up while in use If a cable or connector is too hot to be comfortably han...

Page 15: ...mpressed air to dislocate particulate matter which may be stuck to the vents Caution Do not use a wet cloth or any aerosol type cleaning fluids as this may be ingested by the unit causing damage and t...

Page 16: ...ut connectors 2 4 Certifications CE RoHS WEEE Table 2 Technical Specifications 8 2 Regulatory Compliance The SC0750 SC1000 SC2000 SC3000 System Controllers have been tested and found to comply with pr...

Page 17: ...es These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radi...

Page 18: ...mpact health and the environment In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources we encourage you to use the appropriat...

Page 19: ...replace these reported defects free of charge The equipment must be sent postage and carriage paid Package the equipment in its original shipping case or as appropriate to prevent damage during trans...

Page 20: ...260 Argentia Road Mississauga Ontario L5N 6H7 CANADA Tel 1 905 821 2600 Toll 1 800 668 8752 USA and Canada Fax 1 905 821 2055 http www excelitas com Pages Product OmniCure aspx www excelitas com omnic...

Reviews: