Excalibur RS-330-EDPB Operation Manual Download Page 15

15

Programmable Features Matrix

Feature #12   Manual Transmission Remote Start

Off 

(press “unlock” button to program)

 - DEFAULT

On

  (press “lock” button to program)

Enabling this feature requires a “setup” procedure to be performed that ensures 

the transmission is in neutral before remote start can be performed� See page 8 for 

more information�

User Feature Programming

: Ignition on, off, press valet 5 times

# Feature

Lock Button

Unlock button Trunk button  ”START” button

1  Engine Run Time

10

5

15

20

2  RS Light Confirmation

Steady

Flashing

3  Horn Honk Volume

Low

Hi

On Demand

OFF

4  Pulse Horn/Steady Siren

Pulse LO

Pulse MED

Pulse HI

Steady Siren

5  Lock w/ IGN on

On

Off

6  Unlock w/ IGN Off

On

Off

7  Unlock w/ Trunk release 

On

Off

Installer Feature Programming

: Ignition on, off, press valet 10 times

1  Remote Start Activation

1 press

2 presses

3 presses

4 presses

2  PINK/WHITE Wire Function

Ignition

Accessory

Start

3  Engine Detection

Tachless Hi

Tachless Lo

Tach Wire

Datatach

Crank Only (press Lock + Unlock)

4  Gas or Diesel Engine

Gas

Diesel  

(15 sec.)

Diesel  

(20 sec.)

Diesel  

(30 sec.)

5  Sat. Port Green Wire Function Start

Pulse after start Status

Dome Light

6  Sat. Port Blue Wire Function

Status

Ignition

7  Crank Time

0.7 sec

1 sec

1.5 sec

2.25 sec

8  Low Temp Crank Extender

0ms

200ms

300ms

400ms

9  Door lock outputs

0.8 sec

3 sec

Double Unlock Total Closure

10  Remote Start Lock Control

Off

Lock after start Unlock before 

start

Both

11  Turbo Timer

Off

1 min

2 min

3 min

12 Manual Transmission

On

Off

13  Data Port Protocol

D2D (Trilogix)

ADS (iData)

Feature #13   Data Port Protocol

D2D (Trilogix)

  (press “lock” button to program) 

- DEFAULT

ADS (iData) 

(press “unlock” button to program)

 

This feature determines which data protocol is used on the data ports� Choose this 

based on the interface module being used� 

NOTE: OmegaLink modules support 

both protocols� The ADS protocol is recommended for maximum capabilities�

Installer Programmable Features (cont’d)

Summary of Contents for RS-330-EDPB

Page 1: ...RS 340 EDP Deluxe Keyless Entry Remote Start Operation Guide June 29 2011 Temporary cover Color cover is in a separate file...

Page 2: ...Features 11 Installer Programmable Features 12 Programmable Features Matrix 15 This device complies with FCC Rules part 15 Operation is subject to the following two conditions 1 This device may not ca...

Page 3: ...bleshooting failed remote start attempts as well as in customizing the programmable features The specific opera tions of the lights are described on page 8 The Valet Switch is used to access transmitt...

Page 4: ...emble the transmitter case LOCK Press and release the LOCK button The doors will lock the parking lights will flash and the horn will honk once UNLOCK Press and release the UNLOCK button The doors wil...

Page 5: ...is active If the engine stalls the system will make up to 3 more attempts Each time you park your vehicle set the climate controls to give you the desired interior temperature when you use the remote...

Page 6: ...the vehicle s data network Consult with your installing dealer to find out if any of these functions are available for your vehicle If so confirm each operation with the transmitter and write each fu...

Page 7: ...l honk 3 times activating low voltage start mode To activate low temp starting enter low voltage start mode as described above but before the horn honks press the valet switch 1 time 15 degrees or 2 t...

Page 8: ...ess the programming functions With the system in a locked state simply turn the ignition key to the RUN ON position and press and release the valet switch once Using The Valet Switch Other Remote Star...

Page 9: ...the system in your car has the key to decipher this code and it is not replicable Automatic Transmitter VerificationTM There is also the potential threat of someone who has temporary access to your ve...

Page 10: ...turn on the Unauthorized Transmitter Alert feature Follow the same steps as the Standard Programming but on any transmitter con troller being programmed instead of pressing the lock button press the...

Page 11: ...eady press lock button to program DEFAULT Flashing press unlock button to program This Feature configures the operation of the vehicle s parking lights during the remote start operation The default se...

Page 12: ...button presses press trunk button to program 4 button presses press start button to program This feature allows you to choose the number of button presses AND pulses required on the White Blue activa...

Page 13: ...Gasoline the starter output will occur 3 seconds after the ignitions turn on When in Tachless mode the engine running status is determined 10 seconds after cranking Diesel the starter output will occ...

Page 14: ...ds on the correct connection of the neutral safety wire to the vehicle s parking brake Please refer to the installation manual for details Feature 8 Low Temp Crank Extender 0ms Off press lock button t...

Page 15: ...TE Wire Function Ignition Accessory Start 3 Engine Detection Tachless Hi Tachless Lo Tach Wire Datatach Crank Only press Lock Unlock 4 Gas or Diesel Engine Gas Diesel 15 sec Diesel 20 sec Diesel 30 se...

Page 16: ...Back Cover Color cover is in a separate file...