Installer Programmable Features (cont’d)

Feature #5   Satellite Relay Port Green wire Function

Starter

  

 

 

 

(press the brake pedal 1 time to program) 

 - DEFAULT

Pulse After Engine Start

  (press the brake pedal 2 times to program)

Status Output

   

 

(press the brake pedal 3 times to program)

Domelight

   

 

 

(press the brake pedal 4 times to program)

This feature changes the operation of the green wire (negative) on the satellite relay 

port. This gives you the flexibility to accomodate certain vehicles that require any 

out-of-the-ordinary pulses or remote start timing. 

Starter

 setting operates as a secondary START output. This will have the same 

pulse timing as the large Violet wire on the main harness.  

Pulse After Start

 setting will give a 0.8 second pulse immediately after the engine 

starts and is running.

Status Output

 setting will behave like the ignition output except it turns on 1.5 

seconds earlier than the primary ignition output..

Domelight

 provides domelight supervision output. It will turn on when the system is 

unlocked and after turning the ignition “off”.

Feature #7   Extended Starter Cranking Time

0.7 Second 

(press the brake pedal 1 time to program)

 - DEFAULT

1.00 Second

 

(press the brake pedal 2 times to program)

1.5 Seconds

 

(press the brake pedal 3 times to program)

2.25 Seconds

  (press the brake pedal 4 times to program)

This feature determines the crank time of the 1st start attempt when in “Tachless” 

mode. If the engine doesn’t start on the first attempt, it will retry up to 3 more times 

extending the crank time by an additional 0.2 second with each attempt..

Feature #4   Gasoline Or Diesel Engine

Gasoline

   

 

(press the brake pedal 1 time to program)

 - DEFAULT

Diesel 15 Sec. Delay

  (press the brake pedal 2 times to program)

Diesel 20 Sec. Delay

  (press the brake pedal 3 times to program)

Diesel 30 Sec. Delay

  (press the brake pedal 4 times to program)

This feature changes the system’s timing of the ignition and starter output sequence 

for gas or diesel engines. gasoline: the starter output will occur 3 seconds after the 

ignitions turn on. when in “Tachless” mode, the engine running status is determined 

10 seconds after starting. Diesel: the starter output will occur 15, 20, or 30 seconds 

after the ignitions turn on (allows for glow plug warming). when in “Tachless” mode,

        the engine running status will be determined 40 seconds after cranking. 

Feature #6   Satellite Relay Port Blue wire Function

Status

 

(press the brake pedal 1 time to program)

 - DEFAULT

Ignition

  (press the brake pedal 2 times to program)

Status 

- operates like the PINk ignition output except it turns on 1.5 seconds earlier 

than the PINk ignition #1 output. This is best for activating bypass kits.

Ignition

 - operates with the same timing as the PINk ignition #1 output.

Summary of Contents for RS-250-DP

Page 1: ...RS 250 DP Deluxe Keyless Entry Remote Start Aug 8 2012 Operation Guide Temporary cover Color cover is in a separate file...

Page 2: ...em status and aids in troubleshooting failed remote start attempts as well as in custom izing the programmable features The specific operations of the lights are described on page 5 The Valet Switch i...

Page 3: ...d the parking lights will stay on as long as remote start mode is active If the engine stalls the system will make up to 3 more attempts Each time you park your vehicle set the climate controls to giv...

Page 4: ...it s already engaged step on the brake pedal to turn the engine off This feature will automatically start the engine should the vehicle battery drop be low 11 volts This feature is very useful when t...

Page 5: ...Fast after activating remote start The system is in the process of start ing the engine Remote Starting Diagnostics Whenever the system is placed into Valet Mode the Status Light optional illumi nate...

Page 6: ...n the first code is learned all existing stored codes will be erased Standard Programming Before starting be sure the system is in an unlocked state by using a working transmitter or performing a manu...

Page 7: ...ess the brake pedal 2 times to program 15 Minutes press the brake pedal 3 times to program 20 Minutes press the brake pedal 4 times to program This feature sets the period of time that the engine will...

Page 8: ...associated base starter output time duration see installer feature 7 and monitors the vehicle s voltage level to determine if the engine is running This setting looks for a voltage increase of 0 3v af...

Page 9: ...ogram 2 25 Seconds press the brake pedal 4 times to program This feature determines the crank time of the 1st start attempt when in Tachless mode If the engine doesn t start on the first attempt it wi...

Page 10: ...1 time to program DEFAULT Unlock before start press the brake pedal 3 times to program This feature allows for OEM alarm lock control in relation to remote start operations thus eliminating extra wir...

Page 11: ...2 Brake Pedal x 3 Brake Pedal x 4 1 Engine Run Time 10 5 15 20 2 RS Light Confirmation Steady Flashing Installer Feature Programming Ignition on off press valet 10 times 1 Remote Start Activation 1 p...

Page 12: ...Back Cover Color cover is in a separate file...