Chapter 3
Transmit Mode
DAS-429PCI/Mx: User’s Manual
page 3 - 5
Write
The Channel
x
Interrupt Condition register sets which conditions cause
interrupts to be generated by the modules Bits00 and 01 are used for transmit
channels and bits 02 through 06 are used for receive channels (see
Channel x
Interrupt Condition Register
on page 4-17 in
Chapter 4: Receive/ Monitor Mode
).
Read/Write
The Channel
x
Status register indicates the operational status of the channel.
Use this register to poll the status of the channel or it can be used with
interrupts. When used in conjunction with interrupts, the register indicates the
condition(s) which caused the interrupt. A logic 1 indicates an active bit. You
must reset the status bits. Only the two least significant bits are used for
transmit channels and only bits 02 through 06 are used for receive channels.
(See
Channel x Status Register
on page 4-18 in
Chapter 4: Receive/ Monitor Mode
).
3.2.7
Channel x Interrupt Condition Register
Bit
Description - Interrupt Conditions
07-15
0
02-06
Not used in Transmit mode
01
Transmitter - End of Frame
1
1.
The End of Block interrupt will occur at the completion of transmission of
each
Instruction Block.
00
Transmitter - End of Block
2
2.
The End of Frame interrupt will occur at the completion of transmission of the
final
Instruction Block (or in loop mode, at the end of each loop cycle)
Channel x Interrupt Condition Register
3.2.8
Channel x Status Register
Bit
Description - Interrupt Conditions
07-15
0
02-06
Not used in Transmit mode
01
Transmitter - End of Frame
00
Transmitter - End of Block
Channel x Status Register – Transmit Mode