background image

Programmable Features

CONVENIENCE

SECURITY

INST

ALLER ONL

Y

User Feature Programming: Ignition on, off, press valet 5 times

#  Feature

Lock Button 

(Brake x 1)

Unlock button 

(Brake x 2)

Trunk button  

(Brake x 3)

Start button 

(Brake x 4)

Lock + Unlock 

(Brake x 5)

1  Remote Start Run Time

10 min

5 min

15 min

20 min

2  Flashing Light Confirmations

Unlock: ON

RS: ON

Unlock: ON

RS: Flash

Unlock: Flash

RS: ON

Unlock: Flash

RS: Flash

3  Confirmation Chirp Volume

Low

Med-Low

Med-High

High

4  BROWN Wire: Siren / Pulsed Horn

Pulse LOW

Pulse MED

Pulse HI

Steady Siren

5  Ignition Lock / Unlock

Off

Ign On = Lock Ign. Off = Unlock Lock + Unlock

6  Door Open Bypass for Feat. #5

On

Off

7  Unlock w/ Trunk Release

On

Off

8  RS Activation (Remote)

Start x 1

Start x 2

Start x 3

Start x 4

9  Last Door Arming

Off

On w/o Lock

On w/ Lock

10  Automatic Rearming

Off

On w/o Lock

On w/ Lock

Enhanced

11  Confirmation Chirps

Siren + Horn Siren Only

On Demand

Off

12  Anti-Carjacking

Ignition

Door

Ig Door

Off

13  Secure Code

Read Operation Guide For Programming Instructions

14  Ignition Override

On

Off

15  Alarm Trigger Duration

30 sec

60 sec

90 sec

120 sec

16  Arming Delay

3 sec

15 sec

30 sec

45 sec

17  Open Door Warning Upon Arming

On

Off

Installer Feature Programming: Ignition on, off, press valet 10 times

1  RS Activation (WHITE/BLUE wire)

1 Pulse

2 pulses

3 pulses

4 pulses

2  PINK/WHITE Wire

Ignition

Accessory

Starter

3  Engine Detection

Tachless Hi

Tachless Lo

Tach Wire

Data-tach

Crank Only

4  Gasoline or Diesel Engine

Gasoline

15 sec Diesel

20 sec Diesel

30 sec Diesel

5  Light Relay Function

Dome Light

Start

Ignition

Accessory

Status

6  Blue Sat Port BLUE Wire

Ignition

Status

Pulse After Start 

below freezing

Pulse After 

Engine Off

Horn

7  Crank Time

0.75 sec

1 sec

1.5 sec

2.25 sec

8  Door Lock/Unlock Outputs

0.8 sec

3 sec

Double Unlock

Total Closure

9  Remote Start Lock Control

Off

Lock after 

Start

Unlock before 

Start

Lock + Unlock

10  Turbo Timer

Off

1 min

2 min

3 min

11  Manual Transmission

On

Off

12  Data Port Protocol

Green: DBI

 

Black: DBI

Green: iData

 

Black: iData

Green: DBI

 

Black: iData

Green: iData

 

Black: DBI

13  Alarm Functions 

On

Off

14  Pulse Ign. on Disarm

On

Off

15  Lock On Prewarn

On

Off

16  Starter Interrupt

 Alarm Only

Anti-grind Only

Alarm/Anti-Grind

Automatic

17  Low Temp Crank Extender

 0 ms

200 ms

300 ms

400 ms

18  Arm/Disarm or CH. 4/5

Arm/Disarm

Arm/CH. 5

CH. 4/Disarm

CH. 4/CH.5

19  Horn Relay Function

Horn

Ignition

Trunk Release

Pulse After 

Start

20  Low Current/Motorcycle Mode

On

Off

15

Summary of Contents for AL-XX60-EDPB

Page 1: ...AL XX60 EDPB Deluxe Keyless Entry Security Remote Start System Installation Guide June 20 2014 Temporary cover Color cover is in a separate file 1 ...

Page 2: ... O Input 6 Green Violet Wire Light Relay COM Output 6 White Red Wire Light Relay N C Input 6 Violet Black Wire Horn Relay N O Input 6 Blue Black Wire Horn Relay COM Output 6 Brown Black Wire Horn Relay N C Input 6 6 Pin Secondary Wire Harness 7 Pink Wire 3rd Channel Output 7 White Blue Wire Remote Start Activation Input 7 White Wire Alarm Arm Input 7 Brown Wire Alarm Disarm Input 7 Lt Green Red Wi...

Page 3: ...in mind when deciding which ignition accessory circuits to power Most if not all will be required REQUIRED These wires provide the constant positive 12v power supply for the system s operation CONNECTION Connect these to a constant 12 volt supply with sufficient amperage for remote starting The 12v power supply to the ignition switch is ideal Some vehicle s have low amperage ignition switches in w...

Page 4: ...und Input REQUIRED This input provides negative ground for all system operations CONNECTION Using a properly sized ring terminal connect this wire to the vehicle s chassis Using an existing bolt is preferred but make sure that the connection point is clean and free of dirt grease or paint Bright shiny metal at the connection point is desired Orange Wire Starter Interrupt Output Relay This provides...

Page 5: ...50mA negative output to flash the vehicle s parking lights typically If the vehicle has a positive parking light circuit use the WHITE wire instead CONNECTION Connect this wire to the vehicle s negative parking light circuit It will show ground when the parking lights are on BE SURE NOT TO CONNECT TO THE DIMMER CIRCUIT WHICH WILL CHANGE RESISTANCE TO GROUND AS YOU TURN THE DIMMER KNOB Gray Wire Ho...

Page 6: ...ht circuit White Red Wire Light Relay N C Input This circuit provides the input for the built in 10 amp domelight relay Specifically the normally closed pin pin 87a which is typically only used for polarity reversing circuits This relay can be programmed via installer feature 5 for other functions CONNECTION Connect this wire to constant power or chassis ground as needed for the chosen function Vi...

Page 7: ...Wire OEM Alarm Arm CH4 Output This output provides a 250mA negative pulse when remote start is activated and when the sys tem s alarm is disarmed It can be programmed for 5th channel output with installer feature 18 CONNECTION Connect this wire to the vehicle s OEM alarm disarm circuit Typically it will show ground when the door cylinder key is turned to the unlock position Lt Green Black Wire OEM...

Page 8: ...t BROWN BLACK Horn Relay COM Output BLUE BLACK Horn Relay N O Input VIOLET BLACK 6 PIN POWE Constant 12v Input Ignition 2 Output Constant 12v Start Outp Ignition 1 Input O Accessory Outpu 10 AMP 3rd Cha Remote Start Activation Arm Al Disarm Ala OEM Alarm Arm CH4 Out OEM Alarm Disarm CH5 Outpu Black BLADE Programming interafce Module Data Green Interface Module Data Window mount Receive Transmit Mo...

Page 9: ...K PORT Unlock 2 Output PINK Unlock 1 Output BLUE Constant 12v Output RED Lock Output GREEN 3 PIN SAT RELAY PORT BLUE Accessory Output GREEN Constant 12v Output RED Status Output BLUE 3 PIN SAT RELAY PORT RED Start Output GREEN Constant 12v Output RED Ignition Output BLUE BLADE Harness Port nterafce Module Data Port nterface Module Data Port Antenna Status Light Valet Switch Backup Battery Port Sli...

Page 10: ...he pulse tim ing is programmable by installer feature 8 CONNECTION Connect this directly to the vehicle s all door unlock circuit if a negative pulse is required Otherwise a doorlock interface and or relays are required to convert the output If you are configuring the system for driver s priority unlocking connect this only to the driver s door unlock circuit Pink Wire Unlock 2 Output This provide...

Page 11: ...e for any BLADE cartridge used in lieu of a standard interface module When connected to the OmegaLink OL LOADER this port can also be used to configure all programmable features as well as update the entire system s firmware These functions may require a BLADE cartridge to be installed When utilizing an OmegaLink BLADE module this 20 pin connector is used for the harness that is included with the ...

Page 12: ...n to indicate it has learned the current tach signal If it does not light check your tach connection and start this procedure again Step 4 If the engine has a high idle at startup it may be necessary to allow the idle to settle to around 700 RPM If needed you can press the valet switch 1 time to resample the tach signal The status light will flash off then back on once the signal has been resample...

Page 13: ...y to learn a transmitter controller code To enter a code simply press and release the lock button When the first code is learned all existing stored codes will be erased Special Programming procedure to turn On the UTA feature Use this method to program transmitters or optional controllers and to turn on the Unauthorized Transmitter Alert feature Follow the same steps as the Standard Programming b...

Page 14: ...rogramming turn the ignition key ON then OFF Or it will exit automatically after 10 seconds of no activity RESTORING FEATURE SETTINGS TO FACTORY DEFAULT Step 1 Enter Installer Feature programming DO NOT SELECT ANY FEATURES Step 2 4 button 2 way MODELS Press LOCK UNLOCK or BRAKE x 5 1 button MODELS Press the START button 5 times or BRAKE x 5 The siren horn will sound to indicate reset and exit prog...

Page 15: ...sec 17 Open Door Warning Upon Arming On Off Installer Feature Programming Ignition on off press valet 10 times 1 RS Activation WHITE BLUE wire 1 Pulse 2 pulses 3 pulses 4 pulses 2 PINK WHITE Wire Ignition Accessory Starter 3 Engine Detection Tachless Hi Tachless Lo Tach Wire Data tach Crank Only 4 Gasoline or Diesel Engine Gasoline 15 sec Diesel 20 sec Diesel 30 sec Diesel 5 Light Relay Function D...

Page 16: ...Temporary back cover Color cover is in a separate file IM_AL XX60 EDPB v2_6 20 2014 16 ...